Diagnostic Value of the Early Heart-to-Mediastinum Count Ratio in Cardiac 123I-mIBG Imaging for Parkinson's Disease

Author:

Frantellizzi Viviana1ORCID,Lavelli Valentina2ORCID,Ferrari Cristina2ORCID,Sardaro Angela3,Farcomeni Alessio4,Pacilio Massimiliano5,Borrazzo Cristian5,Pani Roberto6,Rubini Giuseppe2,Vincentis Giuseppe De7

Affiliation:

1. Department of Molecular Medicine, Sapienza, “Sapienza” University of Rome, viale Regina Elena,324, 00161Rome, Italy

2. Nuclear Medicine Unit, Interdisciplinary Department of Medicine – University of Bari “Aldo Moro”, Bari, Italy

3. Interdisciplinary Department of Medicine, Section of Radiology and Radiation Oncology, University of Bari “Aldo Moro”, Bari, Italy

4. Department of Economic and Finance, “Tor Vergata” University of Rome, via Columbia, 2, 00133Rome, Italy

5. Department of Medical Physics, Azienda Ospedaliera Universitaria Policlinico Umberto I, viale del Policlinico 155, 00161Rome, Italy

6. Department of Sciences and Medico-Surgical Biotechnologies, “Sapienza” University of Rome, viale Regina Elena,324, 00161Rome, Italy

7. Department of Radiological Sciences, Oncology and Anatomical Pathology, Sapienza, “Sapienza” University of Rome, viale Regina Elena,324, 00161Rome, Italy

Abstract

Background: Early diagnosis of Parkinson's disease (PD) is of primary importance. The delayed (3-4 h after injection) Iodine-123-Metaiodobenzylguanidine (123I-mIBG) scintigraphy has been proven to be effective in early differential diagnosis for Lewy body disease. But early imaging (15-30 min after injection) has only been marginally studied for its possible diagnostic role. In this prospective study, a threshold for the early Heart-to-Mediastinum (H/M) count ratio has been investigated, obtaining a diagnostic accuracy analogous to conventional, delayed imaging. Methods: One hundred and eight patients with suspected Parkinson's disease (PD) were acquired after 15 and 240 minutes from the injection of 150-185 MBq of 123I-mIBG. The early and late H/M (He/Me and Hl/Ml) were evaluated by drawing Region-of-Interests on the heart and the upper half of the mediastinum. Optimal threshold (Youden index) and overall predictive performance were determined by receiver operating characteristic curve, classifying tentatively patients having an Hl/Ml lower than 1.6 as suffering from PD. Results: He/Me was not significantly different from Hl/Ml (p-value=0.835). The Area-under-curve was 0.935 (95%CI: 0.845-1.000). The He/Me optimal threshold was 1.66, with sensitivity, specificity, and diagnostic accuracy of 95.5%, 85.7 and 90.7% respectively. Conclusions: The He/Me Ratio is almost as accurate as the widely used delayed 123I-mIBG imaging, reducing the burden of delayed imaging but preserving the diagnostic accuracy of the method. Moreover the differential diagnosis in Parkinson's disease can be made in just 25 minutes against the 4 hours currently needed, lowering costs of the healthcare system and improving patients compliance.

Publisher

Bentham Science Publishers Ltd.

Subject

Pharmacology,Radiology Nuclear Medicine and imaging

Reference25 articles.

1. Litvan I.; MacIntyre A.; Goetz C.G.; Wenning G.K.; Jellinger K.; Verny M.; Bartko J.J.; Jankovic J.; McKee A.; Brandel J.P.; Chaudhuri K.R.; Lai E.C.; D’Olhaberriague L.; Pearce R.K.B.; Agid Y.; Accuracy of the clinical diagnoses of Lewy body disease, Parkinson disease, and dementia with Lewy bodies: a clinicopathologic study. Arch Neurol Accuracy of the Clinical Diagnoses of Lewy Body Disease, Parkinson Disease, and Dementia With Lewy Bodies1998,55(7),969-978

2. Gabilondo I.; Llorens V.; Rodriguez T.; Fernández M.; Concha T.P.; Acera M.; Tijero B.; Murueta-Goyena A.; Del Pino R.; Cortés J.; Gómez-Esteban J.C.; Myocardial MIBG scintigraphy in genetic Parkinson’s disease as a model for Lewy body disorders. Eur J Nucl Med Mol Imaging 2019,46(2),376-384

3. Okada Y.; Shiraishi M.; Nakamura H.; Maki F.; Sasaki N.; Hasegawa Y.; Sasaki O.; Nakashima Y.; Usefulness of the combination of iodine-123-metaiodobenzylguanidine scintigraphy and iodine-123-ioflupane scintigraphy in new-onset Parkinson’s disease. Nucl Med Commun 2018,39(11),983-988

4. Orimo S.; Ozawa E.; Nakade S.; Sugimoto T.; Mizusawa H.; (123)I-metaiodobenzylguanidine myocardial scintigraphy in Parkinson’s disease. J Neurol Neurosurg Psychiatry 1999,67(2),189-194

5. Watanabe H.; Ieda T.; Katayama T.; Takeda A.; Aiba I.; Doyu M.; Hirayama M.; Sobue G.; Cardiac (123)I-meta-iodobenzylguanidine (MIBG) uptake in dementia with Lewy bodies: comparison with Alzheimer’s disease. J Neurol Neurosurg Psychiatry 2001,70(6),781-783

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3