An In-House 3D Voxel Dosimetric Tool to Compare Predictive and Post- Treatment Dosimetry in 90Y Radioembolization: A Proof of Concept

Author:

Ferrando Ornella1ORCID,Bampi Rossana1,Foppiano Franca1,Ciarmiello Andrea2

Affiliation:

1. Department of Physics, Sant’Andrea Hospital, ASL5 Spezzino, La Spezia, Italy

2. Department of Nuclear Medicine, Sant’Andrea Hospital, ASL5 Spezzino, La Spezia, Italy

Abstract

Aim: The aim of this study was to implement an in-house dosimetric tool to assess tumour- absorbed doses in pre and post-dosimetry for 90Y radioembolization with resin spheres. Materials and Methods: To perform dosimetric calculations we set up a dosimetric procedure and developed homemade software to calculate tumour absorbed dose and dose volume histograms (DVHs). The method is based on a simplified voxel dosimetry for an estimated 3D absorbed dose and it can be applied to both 99mTc-MAA SPECT/CT and 90Y PET/CT acquisitions for pre and post-dosimetry. We tested the software performance in a retrospective study using the data of 22 patients with hepatocellular carcinoma who underwent radioembolization with 90Y resin spheres in the period 2016-2021. The software calculates tumour doses (mean, minimum and maximum doses) from voxel counts and dose-volume histograms (DVH_spect, DVH_pet) for both 99mTc-MAA SPECT/CT and 90Y PET/CT imaging. DVH_spect and DVH_pet data were analyzed and compared with the aim to assess an agreement between them. Concordance between dosimetric data were evaluated with the Wilcoxon Signed Ranked test, descriptive statistical analysis and Pearson correlation coefficient. Results: The mean administrated activity was 1313 MBq (range 444 MBq - 2200 MBq). Tumour volumes ranged from 75 mL to 1012 mL. The mean absorbed dose for tumour volume was 161 ± 66 Gy (Dm_spect) and 173 ± 79 Gy (Dm_pet). From Wilcoxon Signed Rank Test the differences between the dosimetric data extrapolated from DVH_spect and DVH_pet results were not significant with α = 0.05 (two-sided test). A good linear correlation was found between 99mTc-MAA and 90Y dosimetric data (Pearson correlation coefficient 0.887 p < 0.001). Generally, DVHs calculated on 99mTc-MAA SPECT/CT and 90Y PET/CT gave comparable results, some discrepancies were observed particularly with those patients where SPECT and PET imaging presented a visual mismatching. Conclusion: A simplified 3D dosimetry methodology was implemented and tested retrospectively on patient data treated with 90Y resin spheres. Even if the clinical feasibility of our approach has to be further validated on an extended patient cohort, the preliminary results of our study highlight the potential of the implemented dosimetric tool for tumour dose assessment.

Publisher

Bentham Science Publishers Ltd.

Subject

Pharmacology,Radiology, Nuclear Medicine and imaging

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3