Abstract

Background: New generation PET/CT devices provide quality images using low radiopharmaceutical activities. Dose monitoring is carried out for nuclear medicine personnel, other health personnel, and companions by determining the radiation dose emitted from low-activity patients to the environment. In particular, it is necessary to revise the working conditions of the personnel according to the radiation dose exposed. Aims: It was aimed to reevaluate the radiation dose rate transmitted to the environment from patients injected with 18F-FDG. Materials and Methods: A total of 31 patients (14F, 17M) who underwent 18F-FDG PET/CT imaging were included. The mean 18F-FDG activity of 7.26 ± 1.29 mCi was used for injection. After injection, radiation dose rates (mR/h) were measured at distances of 25, 50, 100, 150, and 200cm for 3 different periods from the level of the head, thorax, abdomen, and pelvis by using a GM counter. Additionally, biological samples such as urine and sweat were taken during 3 different periods. The activity amounts (μCi) in the samples were measured with a well-type counter. Results: Strong correlations were calculated between normalized dose rates obtained by all regions and time. Considering the nuclear medicine staff handling time with a PET/CT patient, the average dose received by staff was calculated between a range of 0.002-0.004 mSv/pt. The radiation dose exposed to the porter and nurse was calculated as 0.049 mSv/pt for the 2nd hour and 0.001-0.007 mSv/pt for the 4th hour, respectively. The companion was exposed to a dose between 0.073-0.147 mSv and 0.024-0.048 mSv for public transport and private car transportation after 4-6 hours of injection (for 30-60 min of travel duration), respectively. For inpatients, the received dose for porters, serving 20min from a distance of 30cm for the 2nd and 4th hours after the PET/CT scan, was 0.049 mSv/pt and 0.048 mSv/pt, respectively. And for nurses serving from a 50cm distance between 1-5 minutes, these values were found to be 0.001-0.007mSv/pt, 0.001-0.007mSv/pt, and 0.001-0.006mSv/pt, respectively. Conclusion: The radiation dose of nuclear medicine staff, porters, nurses, and companions are found to be below the recommended dose limit by the ICRP. According to our results, there is no need for any restrictions for patients, companions, or healthcare personnel in PET/CT units.

Funder

Altınbaş University Scientific Research Fund. Project

Publisher

Bentham Science Publishers Ltd.

Subject

Pharmacology,Radiology, Nuclear Medicine and imaging

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3