Research on the Influence of High-Low Pressure-Volume Ratio and Discharge Pressure on the Heating Performance of Transcritical CO2 Single- Machine Two-Stage Compression Heat Pump Water Heater

Author:

Liu Yefeng1,Yang Wenting1,Hu Jiwei2,Wang Yuqing1,Zhang Hua1

Affiliation:

1. College of Energy and Power Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China

2. Panasonic Compressor (Dalian) Co., Ltd., Liaoning Dalian 116000, China

Abstract

Background: In order to reduce global carbon emissions, a cross-critical CO2 singlemachine two-stage compression system was proposed. Due to the characteristics of cooling on the high-pressure side of the cross-critical cycle and bipolar compression on the single-stage, the discharge pressure and the high-low pressure volume ratio have a great influence on its heating performance. Objective: The purpose of this paper is to explore the influence of high-low pressure-volume ratio and discharge pressure on the heating performance of the system, so as to obtain the optimal operating conditions of the system. Methods: By constructing theoretical calculation formula of discharge pressure, high-low pressurevolume ratio and intermediate pressure, combined with experiments. Results: Under certain working conditions, with the increase of the volume ratio of high-low pressure, the intermediate pressure increases, the heating capacity of the system increases due to the increase of the discharge temperature and the increase of the heat exchange temperature difference on the hot water side, while the heating performance coefficient decreases slowly because the rate of the increase of the power consumption of the compressor is greater than the rate of the increase of heating capacity. With the increase of discharge pressure, the increasing rate of CO2 discharge temperature will gradually decrease at the high-pressure side, so the heating capacity of the system increases rapidly first and then tends to slow down, and the heating performance coefficient increases first and then decreases. There is an optimal value, that is, when the evaporation temperature is -20 °C, the maximum heating capacity can reach 3 kW. The system heat production performance coefficient has an optimal value of 3.29, and the optimal discharge pressure is 8.5 MPa. The optimal discharge pressure will increase with the increase of evaporation temperature. Conclusion: The selection of reasonable high-low pressure volume ratio and the control of discharge pressure can effectively improve the heating performance of cross-critical CO2 single-machine twostage compression heat pump water heater.

Funder

National Key R&D Program

Publisher

Bentham Science Publishers Ltd.

Subject

General Materials Science

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3