Non-invasive Estimation of Haemoglobin Level Using PCA and Artificial Neural Networks

Author:

Lakshmi M.ORCID,Manimegalai P.ORCID

Abstract

Objective: Haemoglobin(Hb) measurement is generally performed by the traditional “fingerstick” test i.e., by invasively drawing blood from the body. Although the conventional laboratory measurement is accurate, it has its own limitations such as time delay, inconvenience of the patient, exposure to biohazards and the lack of real-time monitoring in critical situations. Non-invasive Haemoglobin Measurement (SpHb) has gained enormous attention among researches and can provide an earlier diagnosis to polycythemia, anaemia, various cardiovascular diseases, etc. Currently, Photoplethysmograph signal (PPG) is used for measuring oxygen saturation, to monitor the depth of anesthesia, heart rate and respiration monitoring. But through detailed statistical analysis, PPG signal can provide further information about various blood components. Investigation / Methodology: In this paper, an approach for non-invasive measurement of Hb using PPG, Principal Component Analysis (PCA) and Neural Network is proposed. A transmissive type PPG sensor is developed which is interfaced with Crowduino for the acquisition of PPG. From the obtained PPG signal, Principal Components (PC) are extracted. SpHb is predicted followed by the extraction of features from the PC. The analysis involves the SpHb prediction using a single PC, double PC and finally all the three PC. The predicted SpHb is evaluated with Hblab in terms of R-value, Mean Absolute Error, Mean Squared Error and Root Mean Squared Error. Conclusion: An approach for non-invasive measurement of Hb using Principal Components obtained from the PPG signal is discussed. The SpHb value is compared with the Hblab values. Correlation R-value between SpHb and Hblab is 0.77 when three principal components are used. Mean Absolute Error (MAE), Mean Squared Error (MSE), Root Mean Squared Error (RMSE) between SpHb and Hblab are 0.3, 0.44 and 0.6633 respectively when SpHb is measured with three principal components. It is evident from the result analysis that SpHb shows the promising result when all the three principal components are used. However, one of the limitations of the work is that the population setting chosen for the work does not include paediatric patients, accurately ill patient, pregnant population and surgical patients. With detailed analysis on a wide range of population setting, Hb prediction using PPG is a promising approach for non-invasive measurement.

Publisher

Bentham Science Publishers Ltd.

Subject

Biomedical Engineering,Medicine (miscellaneous),Bioengineering

Cited by 11 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Multi-scale Vision Transformer toward improved non-invasive anaemia detection using palm video;Multimedia Tools and Applications;2024-08-29

2. Point of Care Noninvasive Screening Tool for Early Detection of Anemia using Smartphone;2024 Second International Conference on Emerging Trends in Information Technology and Engineering (ICETITE);2024-02-22

3. Dual mode information fusion with pre-trained CNN models and transformer for video-based non-invasive anaemia detection;Biomedical Signal Processing and Control;2024-02

4. An Efficient, Cost-effective and Reliable Non-invasive Anaemia Detection Method by Analysing Palm Pallor;2024 International Conference on Advancements in Smart, Secure and Intelligent Computing (ASSIC);2024-01-27

5. Contactless Skin Blood Perfusion Imaging via Multispectral Information, Spectral Unmixing and Multivariable Regression;IEEE Open Journal of Signal Processing;2024

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3