Author:
Johnsen Gorm Krogh,Martinsen Ø.G,Grimnes S
Abstract
In vivowater content in the epidermal stratum corneum can be estimated by means of low frequency susceptance measurements. In thein vitrocalibration necessary to find thein vivowater content, the stratum corneum will have a uniform distribution of water across its thickness. However,in vivostratum corneum has an increasing water concentration profile from the outermost towards the innermost parts. This paper will investigate the possibility of estimating the equilibrium water content in thein vivostratum corneum non-invasively from electrical susceptance measurements. Given a known shape of the water concentration profile in thein vivostratum corneum and the dependence of susceptance on the water content, it is possible to calculate the water contentin vivobased on analytically derived expressions for the water concentration profile. A correspondence betweenin vivoandin vitrowater content needed for this purpose is also established.
Publisher
Bentham Science Publishers Ltd.
Subject
Biomedical Engineering,Medicine (miscellaneous),Bioengineering
Cited by
7 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献