Author:
Miao Haixiong,Ye Dongping,Liang Weiguo,Yao Yicun
Abstract
Introduction:
The conventional CD used 10 mm drill holes associated with a lack of structural support. Thus, alternative methods such as a tantalum implant, small drill holes, and biological treatment were developed to prevent deterioration of the joint. The treatment of CD by multiple 3.2 mm drill holes could reduce the femoral neck fracture and partial weight bearing was allowed. This study was aimed to evaluate the effect of osteonecrosis intervention rod versus core decompression using multiple small drill holes on early stages of necrosis of the femoral head.
Method: From January 2011 to January 2012, 60 patients undergoing surgery for osteonecrosis with core decompression were randomly assigned into 2 groups based on the type of core decompression used: (1) a total of 30 osteonecrosis patients (with 16 hips on Steinburg stageⅠ,20 hips on Steinburg stageⅡ) were treated with a porous tantalum rod insertion. The diameter of the drill hole for the intervention rod was 10mm.(2) a total of 30 osteonecrosis patients (with 14 hips on Steinburg stageⅠ,20 hips on Steinburg stageⅡ) were treated with core decompression using five drill holes on the lateral femur, the diameter of the hole was 3.2 mm. The average age of the patient was 32.6 years (20-45 years) and the average time of follow-up was 25.6 months (12- 28 months) in the rod implanted group. The average age of the patient was 35.2 years (22- 43 years) and the average time of follow-up was 26.3 months (12-28 months) in the small drill holes group.
Results:
The average of surgical time was 40 min, and the mean volume of blood loss was 30 ml in both surgical groups. The average of Harris score was improved from 56.2 ± 7.1 preoperative to 80.2 ± 11.4 at the last follow-up in the rod implanted group (p < 0.05). The mean Harris score was improved from 53.8 ± 6.6 preoperative to 79.7 ± 13.2 at the last follow-up in the small drill holes group (p<0. 05). No significant difference was observed in Harris score between the two groups. At the last follow-up, 28 of 36 hips were at the same radiographic stages as pre-operation, and 8 deteriorated in the rod implanted group. 26 of 34 hips were at the same radiographic stage as pre-operation, and 8 deteriorated in the small drill holes group. No significant difference was observed in radiographic stage between the two groups. There was no favourable result on the outcome of a tantalum intervention implant compared to multiple small drill holes.
Discussion:
CD via multiple small drill holes would allow similar postoperative load-bearing and seems to result in similar or even better clinical outcome without the prolonged implantation of an expensive tantalum implant. A tantalum rod intervention and core decompression using multiple small drill holes were effective on the stage I hips rather than stage II hips.
Publisher
Bentham Science Publishers Ltd.
Reference17 articles.
1. Veillette CJ, Mehdian H, Schemitsch EH , et al.
Survivorship analysis and radiographic outcome following tantalum rod insertion for osteonecrosis of the femoral head
J Bone Joint Surg Am
2006;
88
(Suppl 3
)
: 48-55.
2. Shuler MS, Rooks MD, Roberson Jr.
Porous tantalum implant in early osteonecrosis of the hip preliminary report on operative, survival, and outcomes results
J Arthroplasty
2007;
22
: 26-31.
3. Floerkemeier T, Lutz A, Nackenhorst U , et al.
Core decompression and osteonecrosis intervention rod in osteonecrosis of the femoral head clinical outcome and finite element analysis
Int Orthop
2011;
35
: 1461-6.
4. Steinberg ME, Hayken GD, Steinberg DR.
A quantitative system for staging avascular necrosis
J Bone Joint Surg Br
1995;
77
: 34-41.
5. Harris WH.
Traumatic arthritis of the hip after dislocation and acetabular fractures treatment by mold arthroplasty.An end-result study using a new method of result evaluation
J Bone Joint Surg Am
1969;
51
: 737-55.
Cited by
15 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献