The Feasibility and Applications of Non-invasive Cardiac Monitoring in Obese Patients Undergoing Day-case Surgery: Results of a Prospective Observational Study

Author:

Sansone P.,Giaccari L.G.,Colella U.,Coppolino F.,Pace M.C.,Passavanti M.B.,Pota V.,Aurilio C.

Abstract

Aims: This prospective observational study evaluates the utility of non-invasive cardiac monitoring in obese patients in the day-surgery case, considering factors, such as Body Mass Index (BMI) and anaesthesia technique. Background: Obese patients are more likely to be admitted to hospital or to get hospitalized because they are more prone to concomitant diseases and obesity itself is not a contraindication to day surgery. Obese patients are a high-risk patient population that may particularly benefit from monitoring perioperative haemodynamic variations. Methods: In this observational study, we compared haemodynamic variations between overweight or obese and normal weight patients undergoing day-case surgery. We adopted NICOM® as a non-invasive cardiac output monitoring. Objective: The aim of the current study was to investigate the haemodynamic impact of BMI and anaesthesia technique during day-case surgery procedures. The other goal was to evaluate the feasibility and applications of non-invasive cardiac output monitoring among the obese population in day-surgery. Results: 74 patients were included in the study. 34 were overweight or obese (weight 84 ± 10 kg, height 160 ± 10 cm, BMI ≈ 30 kg/m2), 40 were normal weight (weight 63 ± 15 kg, height 160 ± 10 cm, BMI ≈ 22 kg/m2). Compared to normal-weight patients, obese patients show an increase in blood pressure with a return to baseline values at the end of surgery (p < 0.05). The Cardiac Output (CO) shows a similar trend, whereas the heart rate is normal. A decrease in the Cardiac Index (CI) during the operation was noticed in both groups, the one in obese patients (p = 0.24) being greater. In the same way, the Stroke Volume Index (SVI) was lower in obese patients during surgery (p < 0.05). In spinal anaesthesia, the Total Peripheral Resistance Index (TPRI) was not statistically different between the groups of study. As for the TPRI in obese patients, we reported values similar to the ones in non-obese patients in spinal anaesthesia. In local anesthesia, TPRI was higher in obese patients than in non-obese. Conclusion: Cardiovascular alterations in relation to obesity include an increase in blood pressure, CO and SV. An inadequate monitoring of haemodynamic parameters is a risk factor for perioperative complications. NICOM® provides a continuous, non-invasive haemodynamic measurement.

Publisher

Bentham Science Publishers Ltd.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3