Determination of Tyrosine Kinase Inhibitor Icotinib in Rat Plasma using UPLC-MS/MS and its Application In vivo Pharmacokinetic

Author:

Zhao Xuewei1ORCID,Li Ruoyang2,Feng Zhangying3,Chen Shanshan3,Liang Yu3,Gao Jinglin3,Wang Mingxia3

Affiliation:

1. Department of Medicine, Fourth Hospital of Hebei Medical University, Hebei, China

2. Breast Center, Fourth Hospital of Hebei Medical University, Hebei, China

3. Department of Clinical Pharmacology, Fourth Hospital of Hebei Medical University, Hebei, China

Abstract

Objective: The purpose of this study was to develop a UPLC-MS/MS method for the determination of icotinib concentrations in blood plasma. Methods: For plasma sample preparation, protein precipitation with acetonitrile was utilized. Analytes were separated on a Kinetex C18 column using 10 mM ammonium acetate containing 0.2% formic acid and methanol (30:70) as the mobile phase, with a gradient flow rate ranging from 0.2 ml·min-1 to 0.4 ml·min-1. The total chromatographic analysis duration was 4.5 minutes. The UPLC system was connected to a mass spectrometer via an electrospray ionization (ESI) interface operated in positive ion mode. Mass monitoring was conducted in multiple reaction monitoring (MRM) modes, with precursor-to-product transitions being m/z 392.06→304.07 for icotinib and m/z 248.00→120.09 for the internal standard, tinidazole. This method has been used for a pharmacokinetic study in rats that were orally administered a single dose of 30 mg/kg icotinib. Results: The assay showed good linearity over concentration ranges of 1-1000 ng/ml for icotinib, with the correlation coefficient exceeding 0.99. The lower limit of quantitation (LLOQ) was established at 1 ng/ml. Both intra- and inter-day precisions (RSD, %) were below 8.23%. The results demonstrated that stability, matrix effect, extraction recovery, carryover effect and dilution stability were all within the acceptable conditions. The primary pharmacokinetic parameters in SD rats after oral administration of icotinib (30 mg·kg-1 ) were as follows: t1/2 = (2.92 ± 0.87)h, Cmax = (2168.65 ± 268.72)ng/ml, Tmax = (0.70 ± 0.27)h, AUC=(9.69 ± 1.95)ug/mL•h, Vd = (14.51 ± 5.60)L, and CL = (3.19 ± 0.59)L/h. Conclusion: A simple and sensitive UPLC-MS/MS method was developed and validated for the determination of icotinib in pharmacokinetic studies.

Publisher

Bentham Science Publishers Ltd.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3