Thermafil: A New Clinical Approach Due to New Dimensional Evaluations

Author:

Vittoria G.,Pantaleo G.,Blasi A.,Spagnuolo G.,Iandolo A.,Amato M.

Abstract

Background: There are a lot of techniques to obturate the root canals, but lateral condensation of gutta-percha is the most used one. An important aspect of thermafil is the error margin tolerated by the manufacturer in the production of plastic carriers. In literature, there is no evidence about discrepancy percentage between different carriers. It is demonstrated that the error margin of gutta-percha is 0.5% and is 0.2% for metal files (ISO standards). Objective: The aim of this study was to evaluate the real dimensions of thermafil plastic carriers observed by the stereo microscope measuring the dimensional discrepancy between them. Methods: For this study, 80 new thermafil (Dentsply Maillefer) have been selected. 40 thermafil 0.25 and 40 thermafil 0.30. Through 60X stereo microscope, the dimensions of the plastic carrier tips have been measured. The dimensions of the plastic carrier were also measured after a heating cycle. ZL GAL 11TUSM (Zetaline stereo evolution) microscope was used to observe the samples. Measurements were made through a dedicated software (Image Focus). All samples were analysed at 60X. Results: A non-parametric paired test (Wilcoxon test) was used to compare baseline and after heating values; p-values ≤ 0.05 were assumed to be statistically significant. Conclusion: The samples we measured showed a mean value of the diameters in Thermafil 25 that was 0.27 mm, for Thermafil 30 the mean value was 0.33 mm. We have measured a dimensional variable of 8% in the 25 group while in group 30 the maximum possible variation found was 4%, that’s why we propose a new protocol of obturation with thermafil. We can also conclude that a single heating process does not affect clinically the plastic carrier dimensions.

Publisher

Bentham Science Publishers Ltd.

Subject

General Dentistry

Reference22 articles.

1. Gulabivala K, Leung SF. Review of a new root canal obturation technique. Dent Update 1994; 21 (2) : 73-78, 80-83.

2. Emmanuel S, Shantaram K, Sushil KC, Manoj L. An in-vitro evaluation and comparison of apical sealing ability of three different obturation technique - lateral condensation, Obtura II, and Thermafil. J Int Oral Health 2013; 5 (2) : 35-43.

3. Anantula K, Ganta AK. Evaluation and comparison of sealing ability of three different obturation techniques: Lateral condensation, Obtura II, and GuttaFlow: An in vitro study. J Conserv Dent 2011; 14 (1) : 57-61.

4. Ersoy I, Evcil MS. Evaluation of the effect of different root canal obturation techniques using two root canal sealers on the fracture resistance of endodontically treated roots. Microsc Res Tech 2015; 78 (5) : 404-7.

5. Greco K, Carmignani E, Cantatore G. The Thermafil root canal obturation system. G Ital Endod 2011; 25 : 97-109.

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3