Author:
Andreucci Ana Carolina,Baroudi Kusai,Freitas Maiara Rodrigues,Amaral Marina,Aguiar Flavio Baggio,Zanatta Rayssa Ferreira,Liporoni Priscila Christiane Suzy
Abstract
Objective:
To evaluate the color stability and degree of conversion of light-cured resin cement with different activator-initiator systems using LED lights with different wavelengths (polywave x monowave).
Materials and Methods:
Sixteen resin cement samples were made using a circular silicone matrix (7 mm diameter, 0.5 mm thickness) for each of the following tested materials: Variolink Esthetic LC (Ivoclar, color Light+); RelyX Veneer (3M ESPE, color A1); Filtek Z350XT flow resin (3M ESPE, color A1); Allcem Veneer APS (FGM, color A1); NX3 Light cure (Kerr, color A1). Half of the samples were photocured with a monowave LED light (Elipar Deep Cure), and the other half with a polywave LED light (Valo Grand). The initial color of each cement was measured using a high translucency ceramic sample simulating ceramic venner. Color measurements were performed with a reflectance colorimetric spectrophotometer and the data was collected according to the CIE L* a* b* system in two steps. The degree of conversion was measured using an infrared spectrometer by Fourier transform (FTIR / ATR) and the absorbance method. Statistical analysis was performed using ANOVA repeated measures and Tukey’s post hoc tests (p <0.05).
Results:
For the color analysis, there were no significant differences between the cement related to time versus light curing (p = 0.084) and also related to time versus cement versus light curing (p = 0.142). Among the factors, there was only a statistically significant difference for the type of cement (p <0.01). In contrast, for the photocuring device (p = 0.504) and the interaction between them (p = 0.738), there was no significant difference. For the degree of conversion analysis, it showed a statistically significant difference for both factors, resin cements (p <0.01) and light curing units (p <0.01).
Conclusion:
The color stability of RelyX cement is low compared to other cements, while Variolink cement presented the best degree of the conversion value.
Publisher
Bentham Science Publishers Ltd.
Reference26 articles.
1. Ural Ç, Duran İ, Tatar N, Öztürk Ö, Kaya İ, Kavut İ.
The effect of amine-free initiator system and the polymerization type on color stability of resin cements.
J Oral Sci
2016;
58
(2)
: 157-61.
2. Sahyon HBS, Rocha EP, Assunção WG, Santos HP.
Role of adhesive systems on the luting interface’s thickness of ceramic laminate veneers.
Braz Oral Res
2020;
24
(34)
: 57-63.
3. Alqahtani MQ, Aljurais RM, Alshaafi MM.
The effects of different shades of resin luting cement on the color of ceramic veneers.
Dent Mater J
2012;
31
(3)
: 354-61.
4. Turgut S, Bagis B.
Colour stability of laminate veneers: An in vitro study.
J Dent
2011;
39
(39)
: e57-64.
5. Rodrigues RB, Lima E, Roscoe MG, Soares CJ, Cesar PF, Novais VR.
Influence of resin cements on color stability of different ceramic systems.
Braz Dent J
2017;
28
(2)
: 191-5.