Author:
Molina Francisco,Freitas Karina Maria Salvatore,Binz Ordóñez Maria Cristina Rockenbach,Cruz Emerson Flamarion,Henriques Rafael Pinelli,Aguirre Balseca Guillermo Mauricio
Abstract
Objective:
The objective of this study was to evaluate in vitro the shear bond strength of two types of MIM (Metal Injection Molding) technology brackets, one with conventional mesh base and the other with rail-shaped mesh base.
Materials and Methods:
Forty human premolars received the bonding of 2 types of brackets: Group 1- 20 Synergy metal brackets (Rocky Mountain) with conventional mesh base and Group 2-20 H4 brackets (OrthoClassic) with rail-shaped mesh base. Both brackets were bonded with Resilience photopolymerizable resin (OrthoTechnology). The specimens were coupled to a Tinius Olsen universal test machine where the shear test was performed using a chisel. In addition, the amount of remaining resin in tooth crown with the ImageJ program was evaluated and the Adhesive Remnant Index (ARI). Intergroup comparison was performed by the independent t test and Chi-square test.
Results:
There was no statistically significant difference between the groups for any of the measures evaluated indicating that the mesh type of the brackets’ base with MIM technology did not influence the shear bond strength of the brackets (shear bond strength, p=0.191; maximum load registered, p=0.244). There was also no difference between the percentage (p=0.602) and area of remaining resin in the teeth (p=0.805) and IRA (p=0.625) between the Synergy and H4 groups.
Conclusion:
Shear bond strength was similar in the two types of brackets with MIM technology evaluated. In addition, the remaining resin in the dental enamel of two types of brackets were also similar.
Publisher
Bentham Science Publishers Ltd.
Reference20 articles.
1. Chevitarese O, Ruellas ACO.
Braquetes Ortodônticos como utilizá-los
2005.
2. Klocke A, Shi J, Vaziri F, Kahl-Nieke B, Bismayer U.
Effect of time on bond strength in indirect bonding.
Angle Orthod
2004;
74
(2)
: 245-50.
3. Pinto AS, Pinto LAMS, Cilense M, Melo ACM, Terra AMV.
A reciclagem de braquetes na clínica ortodôntica.
Ortodontia
1996;
29
: 63-7.
4. Fleming PS, Johal A.
Self-ligating brackets in orthodontics. A systematic review.
Angle Orthod
2010;
80
(3)
: 575-84.
5. Fleishmann LA, Sobral MC, Santos GC Junior, Habib F.
Estudo comparativo de seis tipos de braquetes ortodônticos quanto à força de adesão.
Rev Dent Press Ortodon Ortop Facial
2008;
13
: 107-16.
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献