Author:
da Silva Vieira Bruno,Cançado Rodrigo H.,Freitas Karina M.S.,Valarelli Fabrício P.,Gobbi Renata C.,de Oliveira Ricardo C. Gobbi
Abstract
Background:
Thermally activated nickel-titanium wires have been widely used by orthodontists due to more constant forces, generation over longer activation spans, greater resistance to permanent deformation, superelasticity characteristics when cyclically loaded, better spring-back and less hysteresis.
Objective:
The purpose of this study was to evaluate the influence of clinical use and sterilization process on the Transition Temperature Range (TTR) of thermoset nickel-titanium wires using Differential Scanning Calorimetry (DSC).
Methods:
Sections from four nickel-titanium wires (0.019 × 0.025-inch) belonging to four different brands were assessed in four different states. Two of the wires were assessed in the “as received” state, one after 60 days of clinical use, and one after 60 days of clinical use and subjected to a sterilization process (autoclaving). The segments of each archwire were tested using DSC at temperatures ranging from −80°C to 150°C at a rate of 10°C/min.
Results:
All the nickel-titanium memory thermoset wires presented with desirable property for clinical use. The shape memory property was not influenced by clinical use and sterilization process.
Conclusion:
There was no change in TTR of the nickel-titanium wires after clinical use and sterilization.
Publisher
Bentham Science Publishers Ltd.
Reference25 articles.
1. Kapila S, Sakima T, Miyazaki S, Sachdeva R.
Currently used orthodontic alloys. Review (1).
Rev Odontol Univ Sao Paulo
1990;
4
(4)
: 334-42.
2. Miura F, Mogi M, Ohura Y, Hamanaka H.
The super-elastic property of the Japanese NiTi alloy wire for use in orthodontics. American journal of orthodontics and dentofacial orthopedics : Official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.
1986;
90
: 1-10.
3. Bradley TG, Brantley WA, Culbertson BM.
Differential Scanning Calorimetry (DSC) analyses of superelastic and nonsuperelastic nickel-titanium orthodontic wires. American journal of orthodontics and dentofacial orthopedics: Official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.
1996;
109
: 589-97.
4. Iijima M, Ohno H, Kawashima I, Endo K, Mizoguchi I.
Mechanical behavior at different temperatures and stresses for superelastic nickel-titanium orthodontic wires having different transformation temperatures.
Dent Mater
2002;
18
(1)
: 88-93.
5. Meling TR, Odegaard J.
Short-term temperature changes influence the force exerted by superelastic nickel-titanium archwires activated in orthodontic bending. American journal of orthodontics and dentofacial orthopedics: Official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.
1998;
114
: 503-9.
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献