Reference Range of CT Value in NC-CBBCT Based on Female Breast Structure

Author:

Wei Wei123,Zhong Wuning1,Kang Wei123,Zhao Xin123,Yi XianLin4,Su DanKe123

Affiliation:

1. Guangxi Medical University Cancer Hospital and Guangxi Cancer Research Institute, Nanning, 530021, P.R. China

2. Guangxi Key Clinical Specialty (Medical Imaging Department), Nanning, P.R. China

3. Dominant Cultivation Discipline of Guangxi Medical University Cancer Hospital (Medical Imaging Department), Nanning, 530199, P.R. China

4. WuMing Hospital of Guangxi Medical University, Nanning, 530199, P.R. China

Abstract

Background: As a new high-resolution three-dimensional CT imaging technology, the essential reference range of CT values in Cone-beam breast computed tomography (CBBCT) has not been established to date. Purpose: To determine the reference range of computed tomography (CT) values in CBBCT for clinical breast examination. Materials and Methods: In total, 913 cases (1167 lateral) were subject to CBBCT. CT values of the glandular tissue, fat and different quadrants and different distances of CBBCT images were analyzed. The nipple and muscle were also evaluated. Results: A total of 672 lateral breasts were included in the normal group for investigation. The reference range of the absolute CT value of the chest wall muscle is -136.68~43.36 HU. The reference range of the absolute CT value of the nipple is 176.39~334.02 HU. The reference range of the absolute CT value of fat is -190.4~-63.67HU, and of glandular tissue is -12.2~199.07HU. Conclusion: Our results firstly established the baseline CT values of Non-contrast CBBCT in female breasts, which will benefit cancer screening and lesion locating. The closer the normal breast fat and glandular tissue is to the nipple, the greater the CT value. The older the age, the lower the density. The CT values of fat are unstable in a distance of less than 5 cm, and the CT values of glandular tissues are relatively stable. The difference between the upper and lower quadrants is significant in the same lateral breast and the same section.

Funder

Guangxi Clinical Research Center for Medical Imaging Construction

National Natural Science Fund of China

Health Department of Guangxi Autonomous Region

Publisher

Bentham Science Publishers Ltd.

Subject

Radiology, Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3