Comparison of R1ρ Imaging Between Rapid Acquisition with Relaxation Enhancement (RARE) and Ultrashort TE (UTE) Sequence in the Assessment of Rat Liver Iron Overload at 11.7T

Author:

Wang Qianfeng1ORCID,Liu Ying1,Xiao Hong2,Yan Fuhua3,Wang He14

Affiliation:

1. Institute of Science and Technology for Brain-Inspired Intelligence, Fudan University, Shanghai, China

2. Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China

3. Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China

4. Human Phenome Institute, Fudan University, Shanghai, China

Abstract

Introduction:: Since the most prominent effect of iron is increasing R2* and R2 relaxation rates, the iron-overload liver shows little signal with conventional T1ρ sequences like RARE. Whereas UTE MR imaging sequences can detect the signal from short T2/T2* relaxation components in tissues. This study aims to evaluate the difference in R1ρ profiles and compare the correlations between RARE-based and UTE-based sequences with LIC in assessing rat liver iron overload. Methods:: Iron dextran (Sigma, 100 mg Fe/ml) was injected into thirty-five rats (25-100 mg/kg body weight), while the rats in the control group were injected with saline (n=5). The liver specimen was taken after one week. A portion of the largest hepatic lobe was extracted to quantify the LIC by inductively coupled plasma, and the remaining liver tissue was stored in 4% buffered paraformaldehyde for 24 h before MRI. Spin-lock preparation with RARE readout and 2D UTE readout pulses were developed to quantify R1ρ on a Bruker 11.7T MR system. Results:: The mean R1ρ value of the rat liver with UTE-based R1ρ sequence was significantly higher compared to the RARE-based R1ρ sequence (p<0.001). Spearman’s correlation analysis (two-tailed) indicated that the R1ρ values were significantly correlated with LIC for both UTE-R1ρ and RARER1ρ sequences (r = 0.727, P < 0.001, and r = 0.712, P < 0.001, respectively). Conclusion:: The current study adds to evidence that there is a correlation between iron concentration and R1ρ. Moreover, the UTE-based R1ρ sequence is more sensitive to the liver iron than the RAREbased R1ρ sequence. R1ρ might serve as a complementary imaging biomarker for liver iron overload quantification.

Publisher

Bentham Science Publishers Ltd.

Subject

Radiology, Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3