Differentiation of Endometriomas from Hemorrhagic Cysts at Magnetic Resonance: The Role of Quantitative Signal Intensity Measurements

Author:

Lupean Roxana-Adelina1ORCID,Ștefan Paul-Andrei2ORCID,Lebovici Andrei2ORCID,Csutak Csaba2ORCID,Rusu Georgeta Mihaela2ORCID,Mihu Carmen Mihaela2ORCID

Affiliation:

1. Histology, Morphological Sciences Department, “Iuliu Hațieganu” University of Medicine and Pharmacy; Louis Pasteur street, number 4, Cluj-Napoca, 400349, Cluj, Romania

2. Radiology and Imaging Department, County Emergency Hospital, Cluj-Napoca; Clinicilor street, number 3-5, Cluj-Napoca, 400006, Cluj, Romania

Abstract

Background: Endometriomas and functional hemorrhagic cysts (FHCs) are a common gynecological encounter. Objective: This study aimed to assess the diagnostic efficiency of magnetic resonance imaging (MRI) using signal intensity measurements in differentiating endometriomas from FHCs. Methods: Forty-six patients who underwent pelvic MRI examinations (endometriomas, n=28; FHCs, n=18) were retrospectively included. The “T2 shading” sign was evaluated subjectively and quantitatively by measuring the T1-T2 signal intensity difference and calculating the percentage of signal decrease between T1 and T2-weighted sequences. The resulted values, along with the measurement of the Apparent Diffusion Coefficient (ADC) and the signal intensity on three diffusion- weighted sequences (DWI) (b50, b400, and b800), were compared between groups by using the Mann–Whitney U test. Also, the receiver operating characteristic analysis was performed for the statistically significant results (P<0.016), and the area under the curve (AUC) was also calculated. Results: The two quantitative assessment methods showed similar efficiency in detecting endometriomas (P<0.001; sensitivity, 100%; specificity, 81.82%; AUC>0.86), outperforming the classic subjective evaluation of the “T2 shading” sign (sensitivity, 92.86%; specificity, 66.67%). ADC (P=0.52) and DWI measurements (P=0.49, P=0.74, and P=0.78) failed to distinguish between the two entities. Conclusion: The quantitative analysis and interpretation of the “T2 shading” sign can significantly improve the differential diagnosis between endometriomas and FHCs.

Publisher

Bentham Science Publishers Ltd.

Subject

Radiology, Nuclear Medicine and imaging

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3