Establishing Protocol-based Dose Metrics for Common Abdomen and Pelvis Computed Tomography Protocols

Author:

Dalah Entesar Zawam12,Alsuwaidi Jamila Salam3,AlKtebi Reem Salim4,AlMulla Muna Abdellatif Ali4,Gupta Priyank4

Affiliation:

1. Department of Head Quarter Diagnostic Imaging, Dubai Health Authority, Dubai, United Arab Emirates

2. College of Medicine, Mohammed Bin Rashid University, Dubai, United Arab Emirates

3. Department of Clinical Support Services and Nursing Sector, Dubai Health Authority, Dubai, United Arab Emirates

4. Department of Radiology, Rashid Hospital, Dubai Health Authority, Dubai, United Arab Emirates

Abstract

Background and Aim: The majority of the existing diagnostic reference levels (DRLs) that have been established for computed tomography (CT) are based on various anatomical locations, such as the head, chest, abdomen, etc. However, DRLs are initiated to improve radiation protection by conducting a comparison of similar examinations with similar objectives. The aim of this study was to explore the feasibility of establishing dose baselines based on common CT protocols for patients who underwent enhanced CT abdomen and pelvis exams. Methods: Dose length product total (tDLPs), volumetric CT dose index (CTDIvol), size-specific dose estimate (SSDE), effective dose (E), and scan acquisition parameters for a total of 216 adult patients, who underwent an enhanced CT abdomen and pelvis exams over a one-year period, were obtained and retrospectively analyzed. Spearman coefficient and one-way ANOVA tests were used to check significant differences between dose metrics and the different CT protocols. Results: The data exhibited 9 different CT protocols to acquire an enhanced CT abdomen and pelvis exam at our institute. Out of these, 4 were found more common, i.e., CT protocols were acquired for a minimum of 10 cases. Triphasic liver demonstrated the highest mean and median tDLPs across all 4 CT protocols. Triphasic liver protocol registered the highest E followed by gastric sleeve protocol with a mean of 28.7 and 24.7 mSv, respectively. Significant differences (p < 0.0001) were found between the tDLPs of anatomical location and the CT protocol. Conclusion: Evidently, wide variability exists across CT dose indices and patient dose metrics relying on anatomical-based dose baseline, i.e., DRLs. Patient dose optimizations require establishing dose baselines based on CT protocols rather than the anatomical location.

Publisher

Bentham Science Publishers Ltd.

Subject

Radiology, Nuclear Medicine and imaging

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3