Assessment of Prescribability and Switchability by Using Multiple Bioequivalence Assessment Approaches

Author:

Micheal Francis1ORCID,Sayana Mohanlal2ORCID,Prasad Rajendra3ORCID,Motial Balamurali M.1ORCID

Affiliation:

1. Department of Chemistry, School of Advanced Sciences, VIT University, Vellore, Tamilnadu 632014, India

2. Department of Pharmacokinetic and Drug Metabolism, Strides Pharma Science Limited, Bangalore, Karnataka 560076, India

3. Department of Pharmacokinetics and Drug Metabolism, Jeevan Scientific Technology Limited, Hyderabad, Telangana 500008, India

Abstract

Background: In the drug development process, an assessment of bioequivalence is an integral part. For the evaluation of generics against the comparator, average bioequivalence approach is the gold standard method. In the recent past, there were many discussions on whether we have the adequate tool to evaluate generics and thereby drug interchangeability (prescribability and switchability) issue is addressed as average bioequivalence approach just considers population mean. Hence, the alternative approaches like population bioequivalence and individual bioequivalence assessment approaches arise as different variances like inter/ intra-subject variance and subject- by-formulation variance along with population mean are considered. Objectives: Methoxsalen, in combination with long-wave UVA radiation, is used in the symptomatic management certain psoriasis. The study was aimed to establish the bioequivalence (BE) of a newly developed methoxsalen capsule (MTX test) with that of a reference methoxsalen capsule (MTX reference) using multiple BE methods (i.e., average [ABE], population [PBE], and individual [IBE]) by utilizing a new LC-MS/MS method. Methods: This is an open-label, randomized, balanced, two-treatment, three-period, three-sequence, crossover, single-dose (20 mg, 2 × 10 mg capsules), comparative, oral BE study conducted in 52 healthy, adult males under fasting conditions. Along with various pharmacokinetic (PK) parameters ABE, PBE, and IBE were also determined in the single study. Results: A non-compartmental model best described the concentration-time data of both MTX test and reference. Both the formulations demonstrated nearly similar values of BE parameters (i.e., AUCo-t, AUC0-∞, Cmax, Tmax, and t1/2). For MTX test, the observed Cmax, AUC0-t, and AUC0- ∞ were 125.16±81.53 ng/mL, 313.73±260.86 ng h/mL, and 321.25±271.85 ng h/mL, respectively. For MTX reference, the values were 127.63±71.60 ng/mL, 329.11±252.91 ng h/mL, and 335.48±264.54 ng h/mL, respectively. : The bioanalytical method was validated over the concentration range 0.100-100.00ng/mL and the coefficient of determination (r2) was ≥ 0.9991. The sensitivity of the method was 0.100 ng/mL with the accuracy and precision values of 115% and 10.54%, respectively. Conclusion: A single dose of MTX test met the ABE criteria of 80.00% -125.00% for Cmax, AUCo- t, and AUC0-∞, against MTX reference. The study outcome by PBE and IBE approaches proved that MTX Test was bio-inequivalent to MTX reference. Using multiple BE assessment methods in a single BE study is a novel approach and may overcome shortcomings of conventional bioequivalence assessment methods.

Publisher

Bentham Science Publishers Ltd.

Subject

Pharmacology (medical),Biochemistry (medical),Clinical Biochemistry,Pharmaceutical Science

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3