Venlafaxine Determination in Pharmaceutical Formulation and Serum by Ion-Selective Electrodes

Author:

Mansour Marwa F.1,El-Moety Mona M. Abd2,El Kady Ehab F.3,El Guindi N.M.2,Schepdael Ann Van1,Aly S.M. El-Moghazy3

Affiliation:

1. Farmaceutische Analyse, Faculteit Farmaceutische Wetenschappen, KU Leuven, Leuven, Belgium

2. National Organization for Drug Control and Research, Giza, Egypt

3. Pharmaceutical Chemistry Department, Faculty of Pharmacy, Cairo University, Cairo, Egypt

Abstract

Background: The application of an ion selective technique for the determination of analyte concentrations is considered one of the most economical techniques for quality control purposes. Objective: To elaborate and investigate the construction and general performance characteristics of potentiometric PVC membrane sensors for venlafaxine cation (Ven+). Method: The sensors are based on the use of the ion association complexes of the venlafaxine cation with phosphotungstate (PT) and silicotungstate (ST) counter anions as ion exchange sites in the plasticized PVC matrix. They are characterized by potentiometric and conductimetric measurements, performed under various conditions. Results: The electrodes showed a fast (response time around 15 s), stable (life span 45 days) and linear (r2 0.995) response for venlafaxine over the concentration range of 5x10-5 - 1x10-2 M venlafaxine hydrochloride. The solubility product of the ion pair and the formation of the precipitation reaction leading to the ion pair, were determined conductimetrically. The electrodes were found to be very selective, precise (RSD < 1%) and applicable to the potentiometric determination of venlafaxine hydrochloride in pure solutions or in pharmaceutical preparation and in biological fluid (serum), without any interference. Validation of the method shows the suitability of the proposed electrodes for use in the quality assessment of venlafaxine hydrochloride. Conclusion: Using only a pH meter in combination with the selective electrodes, drug substance or drug product could be determined accurately in a few seconds. In addition, the in-house made electrodes were tested to monitor venlafaxine in serum. Acceptable results were achieved using the standard addition technique.

Publisher

Bentham Science Publishers Ltd.

Subject

Drug Discovery,Pharmacology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3