Application Potential of Radiomics based on the Unenhanced CT Image for the Identification of Benign or Malignant Pulmonary Nodules

Author:

Zhang Ling1,Zeng Bingliang2,Liu Jiaqi2,Lin Huashan3,Lei Pinggui4,Fan Bing2,Xu Rong2

Affiliation:

1. Medical College of Nanchang University, Nanchang 330036, China | Jiangxi Provincial People's Hospital, Nanchang 330006, China

2. Jiangxi Provincial People's Hospital, Nanchang 330006, China | The First Affiliated Hospital of Nanchang Medical College, Nanchang 330006, China

3. GE Healthcare, Hangzhou 310000, China

4. The Affiliated Hospital of Guizhou Medical University, Guiyang 550000, China

Abstract

Objective:: With the rapid development in computed tomography (CT), the establishment of artificial intelligence (AI) technology and improved awareness of health in folks in the decades, it becomes easier to detect and predict pulmonary nodules with high accuracy. The accurate identification of benign and malignant pulmonary nodules has been challenging for radiologists and clinicians. Therefore, this study applied the unenhanced CT imagesbased radiomics to identify the benign or malignant pulmonary nodules. Methods:: One hundred and four cases of pulmonary nodules confirmed by clinicopathology were analyzed retrospectively, including 79 cases of malignant nodules and 25 cases of benign nodules. They were randomly divided into a training group (n = 74 cases) and test group (n = 30 cases) according to the ratio of 7:3. Using ITK-SNAP software to manually mark the region of interest (ROI), and using AK software (Analysis kit, Version 3.0.0.R, GE Healthcare, America) to extract image radiomics features, a total of 1316 radiomics features were extracted. Then, the minimum–redundancy–maximum–relevance (mRMR) algorithms were used to preliminarily reduce the dimension, and retain the 30 most meaningful features, and then the least absolute shrinkage and selection operator (LASSO) algorithm was used to select the optimal subset of features, so as to establish the final model. The performance of the model was evaluated by using the receiver operating characteristic (ROC) curve, area under the ROC curve (AUC), accuracy, sensitivity and specificity. Calibration refers to the agreement between observed endpoints and predictions, and the clinical benefit of the model to patients was evaluated by decision curve analysis (DCA). Results:: The accuracy, sensitivity, and specificity of the training and testing groups were 81.0%, 77.7%, 82.1% and 76.6%, 85.7%, 73.9%, respectively, and the corresponding AUCs were of 0.83 in both groups. Conclusion:: CT image-based radiomics could differentiate benign from malignant pulmonary nodules, which might provide a new method for clinicians to detect benign and malignant pulmonary nodules.

Publisher

Bentham Science Publishers Ltd.

Subject

Radiology, Nuclear Medicine and imaging

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3