Diagnosis of Benign and Malignant BI-RADS 4 Breast Masses by Contrastenhanced Ultrasound Combined with Shear Wave Elastography

Author:

Weng Lifeng1,Yu Mengxia1

Affiliation:

1. Department of Ultrasound Medicine, Changzhou Second People's Hospital, Changzhou, Jiangsu 213004, China

Abstract

Background:: Breast cancer, one of the most prevalent malignant tumors in females, usually occurs in the breast epithelial tissues. Objective:: The study aimed to explore the diagnostic value of contrast-enhanced ultrasound (CEUS) combined with shear wave elastography (SWE) in the diagnosis of benign and malignant breast masses in BI-RADS (Breast Imaging Reporting and Data System) 4. Methods:: Examination outcomes and clinical information of 83 patients with BI-RADS 4 breast masses were analyzed retrospectively. These included patients who received CEUS, SWE, and pathological examinations. The difference of CEUS in determining the classification of BI-RADS 4 breast masses was evaluated using histopathological outcomes of breast masses as a reference standard. The diagnostic value of CEUS, SWE, and CEUS combined with SWE in the diagnosis of benign and malignant breast masses in BI-RADS 4 was also explored. Results:: Pathological biopsy results revealed 63 malignant masses and 20 benign masses among 83 BI-RADS 4 breast masses, with a 75.9% incidence of malignant masses. After the diagnosis of BI-RADS 4 breast masses with CEUS, SWE, and CEUS+SWE, the incidence of malignancy was 56.6%, 78.3%, and 73.5%, respectively. CEUS+SWE showed higher sensitivity (93.7% vs. 81% and 68.3%), specificity (90% vs. 30% and 80%), positive predictive value (96.7% vs. 78.5% and 91.5%), negative predictive value (81.8% vs. 33.3% and 44.4%), and diagnostic coincidence rate (92.8% vs. 68.7% and 71.1%) than SWE and CEUS alone in diagnosing pathological type of breast masses. Moreover, CEUS combined with SWE exhibited a larger area under the receiver operating characteristic (ROC) curve (0.918) than SWE (0.741, p = 0.028) and CEUS (0.555, p < 0.001) alone in the diagnosis of BI-RADS 4 breast masses. Conclusion:: Overall, the diagnostic value of CEUS+SWE for the pathological type of BI-RADS is preferred over CEUS and SWE alone. CEUS+SWE showed higher values than CEUS and SWE alone in diagnosing BI-RADS 4 breast masses. Specifically, CEUS+SWE can correctly identify benign and malignant masses, reduce unnecessary trauma, and avoid misdiagnosis. In summary, CEUS combined with SWE can serve as an effective diagnostic method and avoid delaying the best treatment opportunity for some malignant lesions.

Publisher

Bentham Science Publishers Ltd.

Subject

Radiology, Nuclear Medicine and imaging

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3