Effect of Breath Training on Image Quality of Chest Magnetic Resonance Freebreathing Sequence

Author:

Jiang Yehai1,Pu Doudou2,Dang Shan2,Yu Nan3

Affiliation:

1. School of Medical Technology, Shaanxi University of Chinese Medicine, Shaanxi, China

2. Department of Medical Imaging, Affiliated Hospital of Shaanxi University of Chinese Medicine, Shaanxi, China

3. School of Medical Technology, Shaanxi University of Chinese Medicine, Shaanxi, China | Department of Medical Imaging, Affiliated Hospital of Shaanxi University of Chinese Medicine, Shaanxi, China

Abstract

Background: Magnetic Resonance Imaging (MRI) plays a role in demonstrating substantial utility in lung lesion imaging, detection, diagnosis, and evaluation. Previous studies have found that free-breathing star VIBE sequences not only have high image quality but also have a high ability to detect and display nodules. However, in our routine clinical practice, we have encountered suboptimal image quality in the free-breathing sequences of certain patients. Objective: This study aims to assess the impact of breath training on the quality of chest magnetic resonance imaging (MRI) obtained during free-breathing sequences. Methods: A total of 68 patients with lung lesions, such as nodules or masses detected via CT examination, were prospectively gathered. They were then randomly divided into two groups: an observation group and a control group. Standard preparation was performed for all patients in both groups before the examination. The observation group underwent 30 minutes of breath training prior to the MRI examination additionally, followed by the acquisition of MRI free-breathing sequence images. The signal intensity (SI) and standard deviation (SD) of the lesion and adjacent normal lung tissue were measured, and the image signal-to-noise ratio (SNR) and contrast signal-to-noise ratio (CNR) of the lesion were calculated for objective image quality evaluation. The subjective image quality of the two groups of images was also evaluated using a 5-point method. Results: MRI examinations were completed in both groups. Significantly better subjective image quality (edge and internal structure clarity, vascular clarity, breathing and cardiac artifacts, and overall image quality) was achieved in the observation group compared to the control group (P<0.05). In addition, higher SNR and CNR values for disease lesions were observed in the observation group compared to the control group (t=4.35, P<0.05; t=5.35, P<0.05). Conclusion: It is concluded that the image quality of free-breathing sequences MRI can be improved through breath training before examination.

Funder

Basic Research Program of Natural Science of Shaanxi Province

National Innovation and Entrepreneurship Training Program for College Students

Publisher

Bentham Science Publishers Ltd.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3