Evaluation of Remodeling and Extrusion of Polyurethane Meniscal Implants after Meniscus Reconstruction using Ultrasonography

Author:

Poboży Tomasz1ORCID,Konarski Wojciech2ORCID,Poboży Kamil3,Domańska Julia4,Konarska Klaudia5

Affiliation:

1. Department of Orthopedic Surgery, Ciechanów Hospital, Ciechanów 06-400, Poland

2. 1Department of Orthopedic Surgery, Ciechanów Hospital, Ciechanów 06-400, Poland

3. Faculty of Medicine, Medical University of Warsaw, Warsaw 01-938, Poland

4. Central Clinical Hospital of the Ministry of Interior and Administration in Warsaw, Warsaw 02-507, Poland

5. Medical Rehabilitation Center, Sobieskiego 47D, Legionowo 05-120, Poland

Abstract

Introduction:: Meniscal tears are among the most common indications for knee arthroscopy. Artificial polyurethane scaffolds have demonstrated efficacy in reducing pain and promoting the growth of normal meniscal tissue, with high absorption rates facilitating full tissue regeneration. Aims:: This study aimed to evaluate the remodeling of polyurethane meniscal implants post-reconstruction using ultrasonography. This imaging technique not only assesses changes in implant properties, such as echogenicity, but also the shape changes during functional examination. Methods:: The assessment of meniscal extrusion, comparing size at rest and under weight-bearing, is an indirect parameter that provides insight into the physical properties of the remodeling implant, with greater extrusion indicating reduced stiffness and inferior physical properties of the meniscus. Ultrasonography has the valuable advantage of allowing for assessment of the blood supply to the meniscus through Power Doppler imaging. Results:: The presence of vessels within the meniscal implants serves as evidence of ongoing remodeling. The study included 35 patients (13 female, 22 male; mean age 41.6 years, range 18-66) who underwent arthroscopic meniscal reconstruction with polyurethane implants, with an average time from surgery of 2.8 years (range 0.3-4.5 years). Results showed complete (29.7%), significant (45.9%), or moderate (16.2%) remodeling into natural meniscal tissue in 91.8% of the implants. Conclusion:: The mean values of extrusion in the supine position and during 90-degree flexion were significantly greater in the operated limb (2.603) compared to the contralateral limb (1.978; t(35) = 2.442; P < 0.05). No significant differences in extrusion were found between the limbs in a standing position, indicating favorable physical properties of the polyurethane meniscal implants. Further ultrasonography studies of meniscal scaffolds are deemed relevant.

Publisher

Bentham Science Publishers Ltd.

Subject

Radiology, Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3