Author:
Benjumea J. M.,Sánchez-Oneto J.,Portela J. R.,Martínez de la Ossa E. J.
Abstract
Background:The use of backpressure regulator valves is widespread in high-pressure processes both at laboratory and pilot plant scales, but being a single step for effluent depressurization, such valves may have some limitations at industrial scale. In an effort to improve the depressurization step, this work studies a system based on the pressure drop of a fluid that circulates through coiled pipes.Method:The equipment, based on three series of variable length coiled pipes, was installed to achieve depressurization of 240 bars in a SCWO pilot plant.Results:The experimental results were compared with those obtained by the modeling carried out using different friction factor correlations from the literature.Conclusion:Among all the correlations tested, the Lockhart–Martinelli correlation showed the best agreement with experimental data. However, it was necessary to obtain an appropriate C parameter to achieve a good agreement with experimental data.
Publisher
Bentham Science Publishers Ltd.
Subject
General Chemical Engineering