Assessment of patient-reported satisfaction and metabolic outcomes following initiation of the second generation of Flash Glucose Monitoring in patients with type 1 diabetes

Author:

Abdullah Al Hayek Ayman1,Alwin Robert Asirvatham1,M Alzahrani Wael1,Al Dawish Mohamed Abdulaziz1

Affiliation:

1. Department of Endocrinology and Diabetes, Diabetes Treatment Center, Prince Sultan Military Medical City, Riyadh, Saudi Arabia

Abstract

Background and Aims: This study aims to assess patient-reported satisfaction and metabolic outcomes following the initiation of the second generation of the Freestyle Libre 2 (FSL2) system in patients with type 1 diabetes (T1D). Methods: This non-randomized single-arm observation study was conducted on 86 patients with T1D living in Saudi Arabia, who were asked to wear the FSL2 for 12 weeks. The demographic data were collected at baseline, while the continuous glucose monitoring (CGM) metrics were gathered, i.e., Glucose Variability (GV) (%), mean Time in Range (TIR), Time Above Range (TAR), Time Below Range (TBR), and average duration of hypoglycemic events were collected at baseline, 6th week and 12 weeks. Further, the Continuous Glucose Monitoring Satisfaction (CGM-SAT) was collected at the end of the follow-up. Results: Compared to the 6th week, significant differences were observed in the low glucose events (p = 0.037), % TIR (p = 0.045), and % below 70 mg/dL (p = 0.047) at 12 weeks. Improvement was seen in the other glucometric variables, but no significant changes were evident (p > 0.05). On completion of the study period, the ambulatory glucose profile (AGP) metrics showed a 74.3 ± 5.01 (mg/dL) FSL2 hypoglycemia alarm threshold and a 213 ± 38.1 (mg/dL) hyperglycemia alarm threshold. A majority of the patients stated that CGM-SAT had benefits (mean score > 3.58), although they felt FSL2 had ‘additional benefits. With regard to the problems with the use of FSL2 majority of the patients stated that FSL2 has minimal discomfort. Conclusion: Using second-generation FSL2 in patients with T1D is positively associated with patient-reported satisfaction and metabolic outcomes.

Publisher

Bentham Science Publishers Ltd.

Subject

Endocrinology,Endocrinology, Diabetes and Metabolism

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3