Affiliation:
1. Department of Pharmaceutical Technology, Faculty of Pharmacy, Hacettepe University, Ankara, Turkey
2. Department of Analytical Chemistry, Faculty of Pharmacy, Hacettepe University, Ankara, Turkey
Abstract
Background:
The number of validated quantification methods for rifampicin, a prototypical Oatp inhibitor, in biological rat samples was limited.
Objective:
This study was conducted to validate a modified reversed-phase liquid chromatographic method for the determination of rifampicin in rat liver tissue according to the current ICH M10 Bioanalytical Method Validation Draft Guideline (2019) for application to samples of in situ rat liver perfusion studies.
Methods:
Liver tissue samples were obtained from recirculatory in situ rat liver perfusion studies. The
analysis was performed on a C18 column with a mobile phase composed of 0.05 M phosphate buffer
(pH 4.58): acetonitrile (55:45, v/v). The assay was validated for selectivity, calibration curve and
range, matrix effect, carry-over, accuracy and precision, reinjection reproducibility, and stability.
Results:
he method was considered selective and stable, without having carry-over and matrix effects.
The calibration curve was linear (R2: 0.9983) within the calibration range (0.5-60 ppm). Accuracy and
precision values fulfilled the required limits. Liver concentrations of rifampicin in liver tissue, obtained
after 60 min perfusion with 10 μM and 50 μM of rifampicin, were 45.1 ± 11.2 and 313.4 ± 84.4 μM,
respectively.
Conclusion:
The bioanalytical method validation was completed and the method was successfully applied for the determination of rifampicin in rat liver tissue.
Funder
Scientific and Technological Research Council of Turkey, TUBITAK
Hacettepe University
Publisher
Bentham Science Publishers Ltd.
Subject
Pharmaceutical Science,Molecular Medicine,Biochemistry,Biophysics