Abstract

Introduction: A reverse-phase high-performance liquid chromatography (RP-HPLC) method was developed and validated for the simultaneous analysis of two drugs, levamisole hydrochloride (LH) and oxyclozanide (OX), in co-formulation for veterinary use. Materials and Methods: The new HPLC method was validated as per the ICH and other guidelines. A C18 column was used with a gradient program; eluent A was an equal mixture of methanol and acetonitrile, and eluent B included a 25 mM phosphate buffer at pH 7.0 containing 30 mM sodium decanesulfonate and triethylamine (50:50:1 v/v) with pH adjusted to 7.0 using H3PO4 [51:49 v/v] .The detection wavelength was set at 220 nm. For the final gradient program, the retention times were 8.2(for LH) and 13.6(for OX) minutes, respectively, at a flow rate of 1 ml/min over 20 minutes run time. Results: The method was precise, specific and robust. The correlation coefficient, R2 was 0.9998 and 0.9999 for LH and OX, respectively in the range of 5 – 280 μg / mL. The percent y-intercepts and percent residual standard deviations were 1.6%/0.4% and 1.4%/1.0% for LH and OX, respectively. The LOD and LOQ of the method were 0.21 μg / mL and 0.62 μg / mL for LH and 0.06 μg / mL and 0.18 μg / mL for OX. The method has an average accuracy of 100.5% for LH and 101.1% for OX when tested on veterinary bolus formulations, and the samples could be stored under typical lab conditions for about 7 days without significant degradation. Conclusion: This HPLC method is suitable for assaying levamisole hydrochloride and oxyclozanide simultaneously from veterinary formulations.

Publisher

Bentham Science Publishers Ltd.

Subject

Pharmaceutical Science,Molecular Medicine,Biochemistry,Biophysics

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3