The Antibacterial Effect of Tetracycline-loaded Mesoporous Silica Nanoparticles in the Gingival Fluid at Implant-abutment Junction: A Randomized Clinical Trial Study

Author:

Mirzaali Fahimeh12,Dizaj Solmaz Maleki1,Shahi Shahriar1,Memar Mohammad Yousef3,Parnia Feridoun2

Affiliation:

1. Dental and Periodontal Research Center, Tabriz University of Medical Sciences, Tabriz, Iran

2. Department of Prosthodontics, Faculty of Dentistry, Tabriz University of Medical Sciences, Tabriz, Iran

3. Infectious and Tropical Diseases Research Center, Tabriz University of Medical Sciences, Tabriz, Iran

Abstract

Introduction: Dental implant failure due to periodontal disease caused by anaerobic pathogens occurs, especially in the first year of implant placement. The aim of this clinical trial study was to compare the antibacterial effect of tetracycline gel and gel containing tetracyclineloaded mesoporous silica nanoparticles (MSNs) in the gingival crevice fluid of the implantabutment junction as a randomized clinical trial study. Materials and Methods: Fourteen patients applying for implants in the posterior mandibular region were included in the study. During the uncovering session, tetracycline gel and gel containing tetracycline-loaded MSNs were placed in two implants and no substance was placed in the control group. Then, in three sessions, including molding, prosthesis delivery, and one month after delivery, the patient's gingival fluid was sampled and the number of bacteria in the gingival fluid was measured by colony-forming units (CFU/mL). Results: The results of this study showed that in all three stages of sampling, the use of tetracycline gel and gel containing MSNs loaded with tetracycline significantly reduced the CFU/mL of gingival crevice fluid compared to the control group. Tetracycline-loaded MSNs gel showed significantly lower CFU/mL than tetracycline gel. The release of tetracycline from nanoparticles keep continue for a longer time compared to tetracycline gel. Conclusion: The use of nano-based delivery systems containing antibiotics inside the implant fixture can reduce the bacterial count of the implant-abutment junction and then improve implant stability.

Funder

Vice-Chancellor for Research (VCR) of Tabriz University of Medical Sciences, Iran

Publisher

Bentham Science Publishers Ltd.

Subject

Biomedical Engineering,Pharmaceutical Science

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3