Evaluation of Pollen Adhesion to Verofilcon-A Soft Contact Lenses

Author:

Mimura Tatsuya,Fujishima Hiroshi,Uchio Eichi,Fukagawa Kazumi,Inoue Yuji,Kawashima Makoto,Kitsu Kazuma,Mizota Atsushi

Abstract

Purpose: A new 1-day disposable soft contact lens (SCL), verofilcon-A, constructed of silicone hydrogel material, has recently become available in Japan. This SCL has a very smooth surface produced by using the SMARTSURFACE ® Technology, and it was expected that pollen particles and protein components would not adhere easily to its surface. We examined the degree of pollen adhesion to the surface of the verofilcon-A material SCL and compared the results with those of other 1-day disposable SCLs (1DSCL). Methods: To determine the number of pollen grains attached to the surface of different types of SCLs, 0.01 mg/ml of cedar pollen solution was dropped onto the surface of 13 types of 1DSCL. After 24 h, each 1DSCL was rinsed in a shaker and washed five times with saline (n = 10 for each 1DSCL type). The number of pollen particles adhered to the 1DSCL and the percentage of surface area occupied by pollen was determined. Results: The number of pollen particles on the 1DSCLs ranged from 0 to 185 in the 200 × 200 µm area. The number of particles was lowest in the delefilcon-A and verofilcon-A SCLs with 0 particles, and the number was higher in the other 11 1DSCLs. The number of pollen particles was negatively correlated with the water content (r = −0.48), oxygen permeability (Dk; r = −0.43), oxygen transmissibility (r = −0.42), and center thickness (r = −0.33) of the 1DSCLs. The pollen adhesion area ranged from 0.0% to 3.1% and was lowest in the delefilcon-A and verofilcon-A 1DSCLs. There were significant differences in the pollen adhesion area between colored 1DSCLs (2.73 ± 1.97%) and clear 1DSCLs (1.03 ± 1.01%, P<0.001) and between hydroxyethyl methacrylate-based 1DSCLs (1.84 ± 1.45%) and silicone hydrogel-based 1DSCLs (0.05 ± 0.16%, P<0.001). Conclusion: These findings indicate that the verofilcon-A 1DSCL processed with SMARTSURFACE™ Technology is an excellent option for SCL users with allergic conjunctivitis during the high pollen season.

Publisher

Bentham Science Publishers Ltd.

Subject

Ophthalmology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3