Fanihagh Farsad,Kremmer Stephan,Anastassiou Gerasimos,Schallenberg Maurice,Steuhl Klaus-Peter,Selbach Michael
Abstract
Purpose:
To determine the correlations and strength of association between different imaging systems in analyzing the retinal nerve fiber layer (RNFL) of glaucoma patients: optical coherence tomography (OCT), scanning laser polarimetry (SLP) and confocal scanning laser ophthalmoscopy (CSLO).
Materials and Methodology:
114 eyes of patients with moderate open angle glaucoma underwent spectral domain OCT (Topcon SD-OCT 2000 and Zeiss Cirrus HD-OCT), SLP (GDx VCC and GDx Pro) and CSLO (Heidelberg Retina Tomograph, HRT 3). Correlation coefficients were calculated between the structural parameters yielded by these examinations. The quantitative relationship between the measured RNFL thickness globally and for the four regions (superior, inferior, nasal, temporal) were evaluated with different regression models for all used imaging systems.
Results:
The strongest correlation of RNFL measurements was found between devices using the same technology like GDx VCC and GDx Pro as well as Topcon OCT and Cirrus OCT. In glaucoma patients, the strongest associations (R²) were found between RNFL measurements of the two optical coherence tomography devices Topcon OCT and Cirrus OCT (R² = 0.513) and between GDx VCC and GDx Pro (R² = 0.451). The results of the OCTs and GDX Pro also had a strong quantitative relationship (Topcon OCT R² = 0.339 and Cirrus OCT R² = 0.347).
GDx VCC and the OCTs showed a mild to moderate association (Topcon OCT R² = 0.207 and Cirrus OCT R² = 0.258). The confocal scanning laser ophthalmoscopy (HRT 3) had the lowest association to all other devices (Topcon OCT R² = 0.254, Cirrus OCT R² = 0.158, GDx Pro R² = 0.086 and GDx VCC R² = 0.1).
Conclusion:
The measurements of the RNFL in glaucoma patients reveal a high correlation of OCT and GDx devices because OCTs can measure all major retinal layers and SLP can detect nerve fibers allowing a comparison between the results of this devices. However, CSLO by means of HRT topography can only measure height values of the retinal surface but it cannot distinguish between different retinal layers.
This may explain the rather poor correlations and associations between CSLO measurements and those of all other imaging devices which makes it difficult to compare HRT 3 nerve fiber data.
These correlations are important in clinical routine especially when different techniques are used in the follow-up of glaucoma patients.
Publisher
Bentham Science Publishers Ltd.
Reference22 articles.
1. Quigley HA, Addicks EM, Green WR.
Optic nerve damage in human glaucoma III Quantitative correlation of nerve fiber loss and visual field defect in glaucoma, ischemic neuropathy, papilledema and toxic neuropathy
Arch Ophtalmol
1982;
100
: 135-46.
2. Kerrigan-Baumrind LA, Quigley HA, Pease ME , et al.
Number of ganglion cells in glaucoma eyes compared with threshold visual field tests in the same persons
Invest Ophthalmol Vis Sci
2000;
41
: 741-8.
3. Sommer A, Katz J, Quigley HA , et al.
Clinically detectable nerve fiber atrophy precedes the onset of glaucomatous field loss
Arch Ophthalmol
1991;
109
: 77-83.
4. Nukada M, Hangai M, Mori S , et al.
Imaging of localized retinal nerve fiber layer defects in preperimetric glaucoma using spectral-domain optical coherence tomography
J Glaucoma
2014;
23
: 150-9.
5. Mwanza JC, Durbin MK, Budenz DL , et al.
Glaucoma diagnostic accuracy of ganglion cell-inner plexiform layer thickness comparison with nerve fiber layer and optic nerve head
Ophthalmology
2012;
119
: 1151-8.