Detection of Acute Optic Neuritis Using Contrast-Enhanced 3-Dimensional Cube T1-Weighted Imaging: A Preliminary Study

Author:

Yang Renjie1,Qu Bing2,Liu Weiyin Vivian3,Liu Changsheng1,Chen Ting4,Li Liang1,Zha Yunfei1

Affiliation:

1. Department of Radiology, Renmin Hospital of Wuhan University, Wuhan 430060, Hubei, People’s Republic of China

2. Department of General Surgery, Renmin Hospital of Wuhan University, Wuhan 430060, Hubei, People’s Republic of China

3. MR Research, GE Healthcare, Beijing 100080, People’s Republic of China

4. Department of Ophthalmology, Renmin Hospital of Wuhan University, Wuhan 430060, Hubei, People’s Republic of China

Abstract

Objective: Objective:We aimed to assess whole-brain imaging with contrast-enhanced (CE) 3-dimensional (3D) Cube T1WI in improving the diagnostic accuracy of acute optic neuritis (ON) compared to conventional CE 2-dimensional (2D) T1WI. Methods: At a field strength of 3 T, CE 3D Cube T1-weighted and conventional CE 2D T1-weighted MR images were retrospectively analyzed for 32 patients (64 optic nerves) with clinically confirmed acute ON. The study cohort included 36 pathological nerves. Image assessments including the overall image quality, clarity of the optic nerve, and visual contrast enhancement were performed by two blinded neuroradiologists using a 4-point scale. The sensitivity, specificity, and accuracy of the conventional 2D T1WI and 3D Cube T1WI were calculated according to the clinical diagnosis. Results: The application of 3D Cube T1WI improved the overall image quality compared to 2D Ax T1WI and 2D Cor T1WI (P < 0.05). The clarity of the optic nerve and the visual contrast enhancement were higher for the 3D Cube T1WI compared to the 2D Ax T1WI and 2D Cor T1WI for at least one reader. The sensitivity, specificity, and accuracy were 89%, 86%, 88% for the 3D Cube T1WI respectively, and 75%, 79%, 77% for the conventional 2D T1WI respectively. The lesions detected by the conventional 2D T1WI were all detected by the 3D Cube T1WI. Conclusion: Our data show that whole-brain imaging with CE 3D Cube T1WI is a viable alternative for the detection of acute ON without sacrificing scanning efficiency.

Publisher

Bentham Science Publishers Ltd.

Subject

Organic Chemistry,Computer Science Applications,Drug Discovery,General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3