3-T MRI in Patients Received Anterior Cervical Discectomy and Fusion Surgery with MAVRIC SL IR Sequence: A Feasibility Study

Author:

Yang Renjie1,Liu Changsheng1,Li Liang1,Chen Liang2,Liu Weiyin Vivian3,Zha Yunfei1

Affiliation:

1. Department of Radiology, Renmin Hospital of Wuhan University, Wuhan 430060, China

2. Department of Orthopaedics, Renmin Hospital of Wuhan University, Wuhan 4300602Department of Orthopaedics, Renmin Hospital of Wuhan University, Wuhan 430060, China

3. MR Research, GE Healthcare, Beijing 100080, China

Abstract

Objective: We aimed to investigate the feasibility of multi-acquisition with variable resonance image combination slab selectivity inversion recovery (MAVRIC SL IR) sequence on 3.0 T MRI in patients with anterior cervical discectomy and fusion (ACDF) surgery compared to bandwidth-optimized short tau inversion recovery (STIR) sequence. Methods: Paired sagittal MR images of MAVRIC SL IR and bandwidth-optimized STIR sequences were acquired and analyzed for 21 patients after ACDF surgery with PEEK cage-plate construct. Quantitative comparisons were made on the metal artifact areas of paired mid-sagittal images. In qualitative analysis, the consistency of fat suppression and visibility of anatomic structures (bone-metal interface, surrounding soft tissues, and spinal cord) were independently assessed, based on a five-point scale by two musculoskeletal radiologists, who were blind to the images and patient details. Results: The application of the MAVRIC SL IR sequence resulted in a significant reduction of 48% in the mean area of metal artifacts (t =-7.141, P < 0.001). Based on the comments received from both the reviewers, MAVRIC SL IR sequence showed greater visibility of the bone-metal interface (P < 0.001), considerable visibility of the surrounding soft tissues (P > 0.05) but worse visibility obtained of the spinal cord (P < 0.001), including the consistency of fat suppression (P < 0.001) relative to the bandwidth-optimized STIR sequence. Conclusion: With significantly reduced metal artifacts, the MAVRIC SL IR sequence can be implemented in patients undergoing ACDF surgery with PEEK cage-plate construct for 3.0 T MRI, despite the poor visibility of the spinal cord.

Publisher

Bentham Science Publishers Ltd.

Subject

Organic Chemistry,Computer Science Applications,Drug Discovery,General Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3