Abstract

Background: Hypertension is one of the most important health problems in the world and irbesartan and amlodipine are used in combination in various dosages for the treatment of high blood pressure. Objective: The aim of this study is to develop a fast, easy, sensitive, accurate, and precise square-wave voltammetry method for simultaneous determination of irbesartan and amlodipine besylate from pharmaceutical formulations at a hanging mercury drop electrode. Methods: In the applied method, since both active substances gave a peak at different potentials, no interference occurred between them. In optimization studies Britton-Robinson buffer of pH 8.0 was chosen, in which the most appropriate peak shape and maximum peak current were observed. At the same time, as a result of instrumental parameter optimization to obtain reproducible results, 6 mV for scan increment, 30 mV for pulse amplitude, and 50 Hz for frequency were found suitable. Results: As a result of the calibration studies of the optimized method, linear working ranges were determined as 1.00-13.08 µg mL-1 for irbesartan and 5.83-16.51 µg mL-1 for amlodipine besylate. Limit of detection and limit of quantitation values were respectively calculated as 0.63 and 1.00 µg mL-1 for irbesartan and 0.50 and 1.98 µg mL-1 for amlodipine besylate. The results of precision values (RSD) ranged from 0.67% to 2.31% for irbesartan and 0.65% to 1.49% for amlodipine besylate. Accuracy values were calculated as -0.15% to 1.63% for irbesartan and -0.07% to 3.78% for amlodipine besylate. The results obtained from the recovery studies ranged from 101.05% to 102.78% and from 98.88% to 102.20% for amlodipine besylate and irbesartan, respectively. Conclusion: After the validation studies of the developed method were carried out, it was successfully applied to pharmaceutical formulations containing these active substances.

Publisher

Bentham Science Publishers Ltd.

Subject

Organic Chemistry,Computer Science Applications,Drug Discovery,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3