Electrochemical Behavior and Square-Wave Stripping Voltammetric Determination of Roflumilast in Pharmaceutical Dosage Forms

Author:

Çelebier Mustafa1ORCID,Dogan Aysegul1ORCID,Süslü İncilay1ORCID,Altınöz Sacide1ORCID

Affiliation:

1. Department of Analytical Chemistry, Faculty of Pharmacy, Hacettepe University, Sihhiye 06100, Ankara,Turkey

Abstract

Background: Bronchial asthma and chronic obstructive pulmonary disease (COPD) are among the most common chronic diseases. Roflumilast is a novel, potent, selective, and long-acting phosphodiesterase 4 (PDE-4) inhibitor for the treatment of bronchial asthma and COPD. It has anti-inflammatory effects, and it has been shown to reduce exacerbations and improve pulmonary function in patients with COPD. Although there have been some other analytical methodologies reported for the determination of roflumilast in pharmaceutical dosage forms, there has not yet been any electrochemical methodology proposed for determination of this unique active pharmaceutical ingredient in its dosage forms. Objective: The aim of this study was to develop an easily applied, selective, sensitive, accurate, and precise square-wave stripping voltammetric (SWSV) method for the determination of roflumilast in its pharmaceutical dosage forms. In addition, the electrochemical behavior of roflumilast was investigated. Methods: The proposed method was based on electrochemical reductioThe proposed method was based on electrochemical reduction of roflumilast at a hanging mercury drop electrode (HMDE) in 0.1 M K2HPO4 and 0.1 M Na2B4O7 (1:1, v/v) buffer at pH 5.0. Two reduction peaks were observed at -1150 mV and -1260 mV with 30 s of accumulation time and -850 mV of accumulation potential time versus Ag/AgCl reference electrode.n of roflumilast at a hanging mercury drop electrode (HMDE) in 0.1 M K2HPO4 and 0.1 M Na2B4O7 (1:1, v/v) buffer at pH 5.0. Two reduction peaks were observed at -1150 mV and -1260 mV with 30 s of accumulation time and -850 mV of accumulation potential time versus Ag/AgCl reference electrode. Results: The higThe highest peak current values with the best peak definition were observed at a frequency of 50 Hz, scan increment of 5 mV, and pulse amplitude 25 mV. The proposed method was validated by evaluating validation parameters such as linearity, sensitivity, repeatability, accuracy, precision, selectivity, recovery, robustness, and ruggedness. A good linear correlation (r=0.9948) was obtained between the electrochemical response of roflumilast and its concentration in the range of 0.74-3.05 μg mL-1 under the optimum conditions. The obtained accuracy results were between 2.04% and -2.04% while the relative standard deviation of the results was at least 2.78% for intraday and inter-day studies. The mean recovery for the real applications was 100.63% ± 0.52. The electrochemical behavior of roflumilast was investigated by cyclic voltammetry. The cyclic voltammogram of roflumilast exhibited two peaks and the reduction reaction was reversible.hest peak current values with the best peak definition were observed at a frequency of 50 Hz, scan increment of 5 mV, and pulse amplitude 25 mV. The proposed method was validated by evaluating validation parameters such as linearity, sensitivity, repeatability, accuracy, precision, selectivity, recovery, robustness, and ruggedness. A good linear correlation (r=0.9948) was obtained between the electrochemical response of roflumilast and its concentration in the range of 0.74-3.05 µg mL-1 under the optimum conditions. The obtained accuracy results were between 2.04% and -2.04% while the relative standard deviation of the results was at least 2.78% for intra-day and inter-day studies. Mean recovery for the real applications was 100.63% ± 0.52%. The electrochemical behavior of roflumilast was investigated by cyclic voltammetry. The cyclic voltammogram of roflumilast exhibited two peaks and the reduction reaction was reversible. Conclusion: This developed and validated SWSV method was applied successfully for the determination of roflumilast in tablet dosage form (Daxas®) to assess active roflumilast content. Since high- -performance liquid chromatography is a dominant technique in industry for quality control of active pharmaceutical ingredients, the finding in the present study demonstrated that square-wave stripping voltammetry could be easily utilized in routine applications to determine roflumilast content in its dosage forms.

Publisher

Bentham Science Publishers Ltd.

Subject

Organic Chemistry,Computer Science Applications,Drug Discovery,General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Contemporary Issues on Pharmaceutical Researches (Part II);Combinatorial Chemistry & High Throughput Screening;2021-03

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3