Electrochemical Sensing of Vitamin C Using Graphene/Poly-Thionine Composite Film Modified Electrode

Author:

Murugan Ridhu Varshini1,Magesh Vasanth2,Vijayalakshmi K.3,Atchudan Raji4,Arya Sandeep5,Sundramoorthy Ashok K.2

Affiliation:

1. Saveetha Medical College and Hospitals, Saveetha Institute of Medical and Technical Sciences (SIMATS), Saveetha University, Saveetha Nagar, Chennai, 602105, Tamil Nadu, India

2. Centre for Nano-Biosensors, Department of Prosthodontics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Poonamallee High Road, Velappanchavadi, Chennai, 600077, Tamil Nadu, India

3. Department of Chemistry, Madras Christian College, East Tambaram, Chennai, 600059, India

4. School of Chemical Engineering, Yeungnam University, Gyeongsan, 38541, Republic of Korea

5. Department of Physics, University of Jammu, Jammu and Kashmir, 180006, India

Abstract

Background: Gastric irritation and kidney problems occur due to excess ascorbic acid content, whereas the lack of ascorbic acid in the human body leads to poor wound healing, muscle degeneration, and anemia. Objectives: Herein, we report the development of an electrochemical sensor for the detection of ascorbic acid using poly-thionine/ graphene (P-Th/Gr) modified glassy carbon electrode (GCE) in 0.1 M phosphate buffer solution (PBS) (pH 7.4). Electrostatically fused graphene affixed with poly-thionine was successfully illustrated for effective voltammetric sensing of ascorbic acid. Methodology: FE-SEM indicated the blended edge of a 2D graphene sheet with a deposited thin layer of polymer, which confirmed the formation of a poly-thionine/graphene composite. The cyclic voltammetry (CV) technique was utilized for the electrochemical assay of ascorbic acid (AsA, Vitamin C). Results: With the increased concentrations of AsA, the oxidation peak current of ascorbic acid increased at 0.0 V, and the overpotential showed a decrease compared to bare GCE. The effect of scan rate on cyclic voltammograms was recorded with 500 μM of ascorbic acid from 10 mV/s to 250 mV/s, which indicated that AsA oxidation is a diffusion-controlled process on poly-thionine/ graphene-modified electrode. Conclusion: It was concluded that a poly-thionine/graphene composite-based sensor could be useful for the determination of ascorbic acid in various biological samples.

Funder

Science and Engineering Research Board (SERB), India

Publisher

Bentham Science Publishers Ltd.

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3