Affiliation:
1. The Orthopaedic Hospital, Århus, Denmark
Abstract
Machined specimens from ten cadaver proximal tibiae were tested in compression to study the variation of mechanical strength with the distance from the joint surface. There was a statistically significant reduction of stiffness and strength with increasing distance from the joint beneath the lateral condyle and the intercondylar area; at the medial condyle no such reduction could be demonstrated. Linear regression analysis showed that the tangent modulus may be used to predict yield strength ( r = 0.92) and ultimate strength ( r = 0.91) when destruction of the specimen is undesirable. One important limitation of the technique employed is that the length of test specimens determines the resolution that can be obtained.
Cited by
52 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献