Affiliation:
1. School of Energy and Power Engineering, Huazhong University of Science and Technology, Wuhan, People's Republic of China
Abstract
The start-up characteristics of a flat miniature loop heat pipe (LHP) with different heat loads were experimentally investigated in this article. Reasons for the difficulties in its start-up were analysed. An overall two-dimensional numerical model was developed to address the heat and mass transfer characteristics in the evaporator of the miniature LHP. The numerical results showed that the performance of the flat miniature LHP could be enhanced by improving the geometrical structure in a limited working space. Effects of thickness of the side wall, height of the compensation chamber, and the wick on system performance were discussed in detail.
Subject
Mechanical Engineering,Aerospace Engineering
Cited by
5 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献