Affiliation:
1. University Engineering Department, Cambridge
Abstract
Two small (90 mm) angle encoders were tested back to back to assess sizes of high-frequency components of error. The results showed errors well below 0.1 seconds of arc at the rotation multiples likely to be relevant for gear noise and vibration testing.
Cited by
12 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献