Affiliation:
1. School of Mechanical and Industrial Engineering, The University of New South Wales
2. Department of Engineering Science, University of Oxford
Abstract
A method has been developed to measure the related rotation of the flanges of a thin-walled tubular specimen during a torsion test. The method, which is based on the Moiré-fringe technique, is capable of use at the high rates of strain encountered during a Hopkinson-bar test, as well as at low rates of strain. In the application described, the specimen gauge length is very short, but the method could be used for specimens of considerably longer gauge length. Direct calibration of the system is easily carried out at low angular velocities. The method can then be used to measure directly the specimen strain during a Hopkinson-bar test, and thus to check the value derived from measuremets of torsional waves in the elastic bars. Results of such comparisons are given, and it is found that the values given by the two method agree well, the differnce being attributable largely to inaccuracies in the torque measurement. The new method permits the determination of specimen deformation during the later stages of the test when multiple wave reflections render the wave analysis iaccurate. In particular, it has been found that the specimen may be subjected to reversed plastic straining, so that the total plastic strain connot be determined from the permenent deformation at the end of the test.
Cited by
6 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献