Affiliation:
1. Department of Mechanical Engineering, University of Glasgow. Graduate of the Institution.
Abstract
This paper records the measurement of the kinematic viscosity of steam at pressures from 200 kg/cm2 to 800 kg/cm2 and at temperatures from 370°C to 650°C. The Rankine-type viscometer used for these determinations was originally designed by Kjelland-Fosterud, who obtained preliminary results from it. To improve the reliability and precision of results, several modifications to the original apparatus have been effected and these are described in the text. The standard deviation of the measured values is ± 1.5 per cent and, in general, these are lower than the accepted values given by Timrot. Further, the results indicate a smaller dependence on pressure than hitherto accepted.
Cited by
20 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献