Survivorship of total joint arthroplasty depends on the durability of fixation and durability of articulation. The metal-on-polyethylene articular couple has been the most widely used. Polyethylene wear (and the associated cytochemical events that culminate in osteolysis) has been identified as a major factor adversely influencing the durability of joint replacement. This stimulated the orthopaedic community to explore the possibility of using alternative bearings with lower wear rates. Hard-on-hard bearings have been shown to be associated with reduced wear. Metal-on-metal bearings have wear rates that are 20-100 times lower than metal on conventional polyethylene. However, patients with metal-on-metal articulations have increased levels of cobalt and chromium in the serum and urine, and this has raised concerns about toxicity, mutagenesis, and hypersensitivity. At this stage there is no epidemiological evidence to suggest that the risk of carcinogenesis is anything more than theoretical. Successful long-term results have been reported with the cast cobalt-chromium metal-on-metal couples of the mid-1960s. Tissues retrieved at revision of these implants did not show the giant-cell inflammatory response associated with polyethylene particles. Several researchers have reported excellent mid-term results with the current generation of high-precision metal-on-metal bearings.

Publisher

SAGE Publications

Subject

Mechanical Engineering,General Medicine

Reference38 articles.

1. Walker P. S. Historical Development of Artificial Joints in Human Joints and their Artificial Replacements, 1977, pp. 253–275 (Thomas, Springfield, Illinois).

2. REPLACEMENT OF ARTHRITIC HIPS BY THE McKEE-FARRAR PROSTHESIS

3. Long-duration metal-on-metal total hip arthroplasties with low wear of the articulating surfaces