Experimental studies on the effect of impeller width on centrifugal compressor stage performance with low solidity vaned diffusers

Author:

Reddy Siva T. Ch.1,Murty Ramana G. V.2,Prasad M. V. S. S. S. M.2,Reddy D. N.3

Affiliation:

1. Sreenidhi Institute of Science and Technology, Ghatakesar, Hyderabad, Andhra Pradesh, India

2. Turbomachinery Laboratory, Corporate R&D Division, Bharat Heavy Electricals Limited, Vikasnagar, Hyderabad, Andhra Pradesh, India

3. University College of Engineering, Osmania University, Hyderabad, Andhra Pradesh, India

Abstract

In an effort to improve the performance of centrifugal compressors, detailed studies were carried out on three different impeller-diffuser configurations covering a wide range of design flow coefficients. These were two-dimensional impellers chosen from a multi-stage compressor series with identical blade geometry. The impeller exit widths covered were 24.5, 18.5, and 11.5 mm, respectively. Extensive experimental studies have been carried out on the chosen stage configurations with parallel walled vaneless diffusers (VLDs) as well as low solidity vaned diffuser (LSD). For all the tested configurations, the aerofoil shape of the diffuser vanes remained same while the diffuser width, setting angle, and solidity were chosen as variables. The performance for each of the stages with LSDs was compared with that of the corresponding VLD. Significant improvement in performance in terms of polytropic efficiency, head coefficient, and static pressure recovery coefficient was observed with LSD vanes as compared with the VLD. Significant improvement in performance was noticed from low flow till design point for all the tested cases. The study revealed that among the tested configurations, there is an optimum width at impeller exit and diffuser for which the performance of the stage was the best. Performance in terms of static pressure recovery coefficient was also evaluated for all the tested configurations and compared. All the studies were conducted for solidity ratio of 0.81. The effect of setting angle on wall static pressure coefficient was also studied at 24° and 28° for the flow coefficients corresponding to 80, 100, and 120 per cent of design flow. Flow surveys at impeller exit for the three cases covering impellers/parallel walled diffusers of different widths have also been carried out to know the flow behaviour in the passage between the impeller and the diffuser.

Publisher

SAGE Publications

Subject

Mechanical Engineering,Energy Engineering and Power Technology

Reference7 articles.

1. Senoo Y. Low solidity circular cascade for wide flow range blower. In Proceedings of Advanced Concepts of Turbomachinery, Fluid Dynamics Institute, Hanover, New Hampshire, 1981, pp. 1–8.

2. The design and performance results of simple flat plate low solidity vaned diffusers

3. Effect of the setting angle of a low-solidity vaned diffuser on the performance of a centrifugal compressor stage

4. Performance and wall static pressure measurements on centrifugal compressor diffusers

Cited by 7 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3