Three- and four-element Windkessel models: Assessment of their fitting performance in a large cohort of healthy middle-aged individuals

Author:

Segers P1,Rietzschel E R2,De Buyzere M L2,Stergiopulos N3,Westerhof N4,Van Bortel L M5,Gillebert T2,Verdonck P R1

Affiliation:

1. Cardiovascular Mechanics and Biofluid Dynamics, IBiTech, Ghent University, Belgium

2. Department of Cardiovascular Diseases, Ghent University Hospital, Belgium

3. Laboratory of Haemodynamics and Cardiovascular Technology, EPFL Lausanne, Switzerland

4. ICar-VU, Laboratory for Physiology, Free University Amsterdam, The Netherlands

5. Heymans Institute of Pharmacology, Ghent University Hospital, Belgium

Abstract

Lumped-parameter models are used to estimate the global arterial properties by fitting the model to measured (aortic) pressure and flow. Different model configurations coexist, and it is still an open question as to which model optimally reflects the arterial tree and leads to correct estimates of arterial properties. An assessment was made of the performance of (a) the three-element Windkessel model (WK3) consisting of vascular resistance R, total arterial compliance C, and characteristic impedance Zc; (b) a four-element model with an inertance element L placed in parallel with Zc (WK4-p); and (c) a four-element model with L placed in series with Zc (WK4-s). Models were fitted to data measured non-invasively in 2404 healthy subjects, aged between 35 and 55 years. It was found that model performance segregated into two groups. In a group containing 20 per cent of the dataset (characterized by low blood pressure and wave reflection) the WK4-p model outperformed the other models, with model behaviour as envisioned by its promoters. In these cases, the WK3 and WK4-s models led to increased overestimation of total arterial compliance and underestimation of characteristic impedance. However, in about 80 per cent of the cases, the WK4-p model showed a behaviour that was very similar to that of the WK3 and WK4-s models. Here, the WK4-s model yielded the best quality of fit, although model parameters reached physically impossible values for L in about 12 per cent of all cases. The debate about which lumped-parameter model is the better approximation of the arterial tree is therefore still not fully resolved.

Publisher

SAGE Publications

Subject

Mechanical Engineering,General Medicine

Reference25 articles.

Cited by 69 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3