Clinical wear behaviour of ultra-high molecular weight polyethylene cups paired with metal and ceramic ball heads in comparison to metal-on-metal pairings of hip joint replacements

Author:

Semlitsch M1,Willert H G2

Affiliation:

1. Sulzer Orthopaedics Limited Winterthur, Switzerland

2. University of Göttingen Department of Orthopaedic Surgery Germany

Abstract

In the course of 30 years of hip endoprosthetics, a number of material combinations for the cups and balls of total hip prostheses have proven successful under clinical conditions. Favourably priced hip prostheses with polyethylene cups and metal balls are available for older patients with a moderate range of activity. Polyethylene wear of 100-300 μm/year is to be expected with these models. Ceramic balls (aluminium oxide for diameters 32 and 28 mm and zirconium oxide for 22 mm) paired with polyethylene cups are recommended for patients with a life expectancy of 10 to 20 years, because the expected polyethylene wear rate with this material combination is only 50-150 μm/year. In other words, the life cycle of the polyethylene cup is doubled, when it is paired with a ceramic ball. A similar polyethylene wear rate is also to be expected with oxygen-deep-hardened TiAlNb metal balls, which are currently the subject of a clinical field study. Last but not least, CoCrMoC metal-metal and Al2O3 ceramic-ceramic pairings, which have the lowest wear rate of 2-20 μm/year, are available for highly active patients with a life expectancy of more than 20 years. As far as the cup-ball pairing is concerned and under the current pressure of costs, the surgeon should be able to select the optimum hip prosthesis model for every patient from these three categories.

Publisher

SAGE Publications

Subject

Mechanical Engineering,General Medicine

Reference56 articles.

1. Semlitsch M., Willert H. G. Gewebsveränderungen im Bereiche metallischer Hüftgelenke; mikroanalytische Untersuchungen mittels Spektrophotometrie, Elektronenmikroskopie und der Elektronenstrahl-Mikrosonde. 6. Internationales Symposium für Mikrochemie, Graz, 1970, pp. 79–102 (Verlag der Wiener Medizinischen Akadamie).

2. REPLACEMENT OF ARTHRITIC HIPS BY THE McKEE-FARRAR PROSTHESIS

3. COMPLETE REPLACEMENT ARTHROPLASTY OF THE HIP BY THE RING PROSTHESIS

Cited by 106 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com