Kinematics of the MATCO™ hip simulator and issues related to wear testing of metal-metal implants

Author:

Medley J B1,Krygier J J2,Bobyn J D2,Chan F W2,Lippincott A3,Tanzer M2

Affiliation:

1. University of Waterloo Department of Mechanical Engineering Canada

2. Montreal General Hospital and McGill University Jo Miller Orthopaedic Research Laboratory Canada

3. Engineering Consulting Services Prior Lake, Minnesota, United States of America

Abstract

Metal-metal hip implants have been used clinically in Europe to reduce the risk of wear particle induced osteolysis. Joint simulator devices could provide useful information for design improvement of the modern generation of metal-metal hip implants. Early wear results for metal-metal hip specimens were obtained using a MATCO™ hip simulator. A detailed kinematic analysis was developed for the MATCO™ simulator and applied to two of the wear experiments to predict the starting surface motion, contact zone and lubricant film thickness. It was shown that points on cup surfaces were not subjected to a reciprocating interaction with the head during wear at the beginning of testing but as wear proceeded, it was suggested that, in some cases, reciprocating interaction did occur on the cup surface. Comparison between simulator and in vivo kinematics suggested a more realistic representation for cup than for head wear. In the simulator, the Hertzian contact zone moved in a circular path over the cup surface and changed in size in correspondence with the applied load. Elastohydrodynamic lubrication was considered to be possible in the simulator, with estimated fluid film thickness as great as 0.1 μm. However, such thick films were not likely to have occurred at the start of the two wear tests which were examined in detail, although some mixed film lubrication might have accounted for the relatively low wear of one of the specimens. The inclusion of kinematic details, contact mechanics and elastohydrodynamic lubrication analysis in simulator testing protocols and in design of metal-metal hip implants was recommended.

Publisher

SAGE Publications

Subject

Mechanical Engineering,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3