Can cobalt levels estimate in-vivo wear of metal-on-metal bearings used in hip arthroplasty?

Author:

Khan M12,Kuiper J H12,Richardson J B12

Affiliation:

1. Institute of Orthopaedics, Robert Jones and Agnes Hunt Orthopaedics Hospital, Oswestry, UK

2. Centre for Science and Technology in Medicine, Keele University Hospital, Keele, UK

Abstract

High levels of cobalt and chromium ions are detected in the blood and urine of patients with metal-on-metal (MoM) hip replacement. These elements are released as a result of wear at the bearing surfaces. Wear rates depend on a multitude of factors, which include the bearing geometry, carbon content, manufacturing processes, lubrication, speed and direction of sliding of the surfaces, pattern of loading, and orientation of the components. In-vivo wear of MoM bearings cannot be reliably measured on X-rays because no distinction can be made between the bearing surfaces. Hip simulator studies have shown that wear rates are higher during the initial bedding-in phase and subsequently drop to very low levels. Accordingly, metal ion levels would be expected to decrease with the use of the bearing, measured as implantation time following surgery. However, several clinical studies have found that metal ion levels either gradually rise or fluctuate instead of decreasing to lower levels. Moreover, hip simulator studies predict that large-diameter bearings have lower wear rates than small-diameter bearings. In clinical studies, however, metal levels in patients with large-diameter bearings are unexpectedly higher than those in patients with small-diameter bearings. As a consequence, high cobalt ion levels in patients do not necessarily imply that their MoM bearings produce much wear debris at the time that their levels were measured; it may simply be due to accumulation of wear debris from the preceding time. Exercise-related cobalt rise may overcome this limitation and give a better assessment of the current wear status of a MoM bearing surface than a measure of cobalt levels only.

Publisher

SAGE Publications

Subject

Mechanical Engineering,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3