Evaluation of a new fluoroscopy-based navigation system in the placement of the femoral component in hip resurfacing

Author:

Gravius S1,Belei P2,de la Fuente M2,Radermacher K2,Mumme T3

Affiliation:

1. Department of Orthopaedic Surgery and Traumatology, Rheinische-Friedrich-Wilhelms University, Bonn, Germany

2. Chair of Medical Engineering, RWTH Aachen University, Aachen, Germany

3. Department for Orthopaedics and Trauma Surgery, RWTH Aachen University, Aachen, Germany

Abstract

Prosthesis-specific mechanical alignment instruments for the precise and reproducible positioning of the femoral component constitute one of the major improvements in modern hip resurfacing prostheses. However, mechanical failure of the femoral component is mostly attributable to the surgical technique, and in particular to notching of the femoral neck. In order to evaluate a novel computer-assisted fluoroscopy-based planning and navigation system, six DUROMTM hip resurfacing prostheses were implanted into artificial femurs by means of computer-assisted fluoroscopy-based navigation and prosthesis-specific mechanical alignment instruments. Subsequently, the planning and navigation system was tested within the scope of a cadaver study on three fixed whole-body preparations (six femurs). The average difference between planned and actual angle of the prosthesis was 0±0.7° for fluoroscopy-based navigation versus 6.5±7.8° for the in-vitro use of the prosthesis-specific mechanical alignment instruments, and 1±1.4° for fluoroscopic navigation in the cadaver study. The average discrepancy between planned and actual anterior offset was −1.2±1.2 mm versus 0.8±4 mm, and 0.3±2.2 mm in the cadaver study, and the time required for the total of five planning and navigation steps was 17.2±1.5 min versus 14±0.8 min and 20.2±2.5 min respectively. No notching of the femoral neck occurred under fluoroscopy nor under conventional treatment. During in-vitro studies, use of the computer-assisted fluoroscopy-based planning and navigation system resulted in enhanced accuracy compared with conventional prosthesis-specific mechanical alignment instruments. The system has yielded initial promising results within the scope of the cadaver study.

Publisher

SAGE Publications

Subject

Mechanical Engineering,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3