Stress shielding and stress concentration of contemporary epiphyseal hip prostheses

Author:

Cristofolini L1,Juszczyk M1,Taddei F1,Field R E2,Rushton N3,Viceconti M1

Affiliation:

1. Laboratorio di Tecnologia Medica, Istituto Ortopedico Rizzoli, Bologna, Italy

2. Orthopaedic Research Unit, St Helier Hospital, London, UK

3. Orthopaedic Research Unit, University of Cambridge, Cambridge, UK

Abstract

After the first early failures, proximal femoral epiphyseal replacement is becoming popular again. Prosthesis-to-bone load transfer is critical for two reasons: stress shielding is suspected of being responsible for a number of failures of early epiphyseal prostheses; stress concentration is probably responsible of the relevant number of early femoral neck fractures in resurfaced patients. The scope of this work was to experimentally investigate the load transfer of a commercial epiphyseal prosthesis (Birmingham Hip Replacement (BHR)) and an innovative prototype proximal epiphyseal replacement. To investigate bone surface strain, ten cadaveric femurs were instrumented with 15 triaxial strain gauges. In addition the cement layer of the prototype was instrumented with embedded gauges to estimate the strain in the adjacent trabecular bone. Six different loading configurations were investigated, with and without muscles. For the BHR prosthesis, significant stress shielding was observed on the posterior side of the head—neck region (the strain was halved); a pronounced stress concentration was observed on the anterior surface (up to five times in some specimens); BHR was quite sensitive to the different loading configurations. For the prototype, the largest stress shielding was observed in the neck region (lower than the BHR; alteration less than 20 per cent); some stress concentration was observed at the head region, close to the rim of the prosthesis (alteration less than 20 per cent); the different loading configurations had similar effects. Such large alterations with respect to the pre-operative conditions were found only in regions where the strain level was low. Conversely, alterations were moderate where the strain was higher. Thus, prosthesis-to-bone load transfer of both devices has been elucidated; the prototype preserved a stress distribution closer to the physiological condition.

Publisher

SAGE Publications

Subject

Mechanical Engineering,General Medicine

Cited by 24 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3