Short-term repeatability of joint space width measurements using a magnetic resonance imaging compatible knee positioning device

Author:

Koff M F1,Stanley D W2,Weishaar P J3,Amrami K K3,Kaufman K R4

Affiliation:

1. Department of Radiology and Imaging, Hospital for Special Surgery

2. GE Healthcare

3. Department of Radiology, Mayo Clinic

4. Department of Orthopedic Surgery, Mayo Clinic

Abstract

The purpose of this study was to evaluate a magnetic resonance imaging (MRI) compatible knee positioning device to aid in minimizing intratechnologist and intertechnologist differences of minimum joint space width (JSW) measurements. Five subjects were scanned by two separate technologists, with and without an MRI-compatible positioning device. A semi-automated program calculated the minimum JSW of the tibiofemoral and patellofemoral joints. The scan-to-scan repeatability was evaluated from measurements between serial scans without subject repositioning, and the intratechnologist and intertechnologist repeatabilities were evaluated when the subject was removed from the magnet and repositioned by an individual technologist. The root mean square (RMS) error of the JSW measurements was also calculated. All measures of scan-to-scan repeatability and intratechnologist repeatability were unchanged with the MRI-compatible positioning device. The intertechnologist repeatability decreased from 0.70 to 0.42 mm, and the RMS error was significantly reduced ( P = 0.0006) from 0.26 to 0.15 mm for the tibiofemoral joint. The variability of patellofemoral JSW measurements increased when using the positioning device; however, the increases were not statistically significant. The intertechnologist repeatability increased from 1.55 to 1.79 mm, and the RMS error increased from 0.58 to 0.73 mm. The MRI-compatible positioning device was successful at reducing JSW measurement variability at the tibiofemoral joint. The increase in measurement variability at the patellofemoral joint may be due to local incongruities of the articular surfaces. An MRI-compatible positioning device may be beneficial for quantitative longitudinal studies evaluating knee joint health.

Publisher

SAGE Publications

Subject

Mechanical Engineering,General Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3