Affiliation:
1. School of Mechanical Engineering, University of Bath
Abstract
The secondary source method forms the British Standard for pump fluid-borne noise testing. This is a powerful technique but requires care in order to produce accurate results. This paper describes practical aspects for implementing the method. The requirements for the test rig, data acquisition system and analysis are detailed. The British Standard specifies that either mathematical modelling or linear interpolation is used on the source impedance measurements. A method for smoothing the impedance results is described in this paper, which is shown to give more repeatable results than linear interpolation. Some physically realistic mathematical models of pump impedance are described, and their use in determining the internal flow ripple discussed.
Subject
Mechanical Engineering,Control and Systems Engineering
Cited by
31 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献